Electrical Adjustments
No.
Adjustment Item
30
Real/Cinema GAMMA 14
31
Real/Cinema GAMMA 15
Group 100 H8 Option
0
Lamp Time Monitor
1
RS232C Baudrate
2
3
Cooling Time
4
Hi-Land SW
5
6
Lamp Total Time
7
Lamp Dim level (Eco)
8
9
Reset SW
10
Color Shading SW
11
RC Enable/Disable
12
Lamp Dim Level
13
Lamp Warning Time
14
15
Video Mute Forced Off
16
Safety FAN Control Fix SW
17
HDCP Option
18
HDCP Reset
19
Group: 101PW Option
0
Shootout Mode
1
V-Sync SW
2
NOBRAND
3
4
HDCP OverScan Rate
Group: 110 Dimmer Processing
0
DIMMER_CTRL_LEVEL1
1
DIMMER_CTRL_LEVEL2
2
DIMMER_CTRL_LEVEL3
3
DIMMER_CTRL_LEVEL4
4
DIMMER_CTRL_LEVEL5
5
DIMMER_CTRL_LEVEL6
6
DIMMER_CTRL_LEVEL7
7
DIMMER_CTRL_LEVEL8
8
DIMMER_CTRL_LEVEL9
9
DIMMER_CTRL_LEVEL10
10
DIMMER_CTRL_LEVEL11
11
DIMMER_CTRL_LEVEL12
12
DIMMER_CTRL_LEVEL13
13
DIMMER_CTRL_LEVEL14
14
DIMMER_CTRL_LEVEL15
15
DIMMER_AVERAGE_POINT
16
DIMMER_AVERAGE_DATA
17
DIMMER_LEVEL_AUTO
18
DIMMER_LEVEL_NONAUTO
Group: 111 Fan Control
0
FAN_TEMP_A_WARNING
1
FAN_TEMP_B_WARNING
2
FAN_TEMP_C_WARNING
3
FAN_TEMP_B-A_WARNING
4
FAN_TEMP_C-A_WARNING
5
FAN_CONTROL_SW
6
FAN_1_SPEED_CTRL
7
FAN_2_SPEED_CTRL
8
9
FAN_1_SPEED_MONI
10
FAN_2_SPEED_MONI
11
12
FAN_TEMP_A_MONI
13
FAN_TEMP_B_MONI
14
FAN_TEMP_C_MONI
15
16
TEMP_UPWARNING_TIME
17
NOR_TEMP_FAN1_MIN
18
NOR_TEMP_FAN1_MAX
19
NOR_TEMP_FAN2_MIN
20
NOR_TEMP_FAN2_MAX
21
22
23
NOR_VALU_FAN1_MIN
24
NOR_VALU_FAN1_MAX
25
NOR_VALU_FAN2_MIN
26
NOR_VALU_FAN2_MAX
27
28
29
ECO_TEMP_FAN1_MIN
Initial Value
Range
Input source / Description
469/497
0 ~ 1023
424/497
0 ~ 1023
0~8738
Read Only
0 ~ 1
0: 19200bps1: 9600bps
3
1 ~ 15
Cooling time1:30 sec.3:90 sec.15:450 sec.
0
0 ~ 3
0: Normal Mode1~3: High-Land Mode 1-3
0~65535
Read only
0 ~ 15
0 ~ 10
Resets User Setting data when this value is set to 10
0 ~ 1
0:Color Compensation Off, 1:Color Compensation On
0
0 ~ 3
0:Enable 1:Disable
10
0 ~ 15
0~65535
0 ~ 1
0:VideoMuteOn(Normal) 1:Video Mute Forced Off
0 ~ 5
0:Normal 1:Normal Min2:Normal Max3:Eco Min4:Eco Max
0
0 ~ 3
0: XGA 1; other than XGA
0
0 ~ 10
0
0 ~ 1
1: Shoot Out Mode Enable0: Disable
0
0 ~ 1
0: No Sync 1: Sync with Vertical sync
0
0 ~ 1
0:Normal1:NOBRAND
0
0 ~ 5
7
0~255
Dimmer Brightness Level1 Data: Dimmer Level1 when less than this value.
14
0~255
Dimmer Brightness Level2 Data: Dimmer Level2 when less than this value.
21
0~255
Dimmer Brightness Level3 Data: Dimmer Level3 when less than this value.
28
0~255
Dimmer Brightness Level4 Data: Dimmer Level4 when less than this value.
35
0~255
Dimmer Brightness Level5 Data: Dimmer Level5 when less than this value.
42
0~255
Dimmer Brightness Level6 Data: Dimmer Level6 when less than this value.
49
0~255
Dimmer Brightness Level7 Data: Dimmer Level7 when less than this value.
56
0~255
Dimmer Brightness Level8 Data: Dimmer Level8 when less than this value.
63
0~255
Dimmer Brightness Level9 Data: Dimmer Level9 when less than this value.
70
0~255
Dimmer Brightness Level10 Data: Dimmer Level10 when less than this value.
77
0~255
Dimmer Brightness Level11 Data: Dimmer Level11 when less than this value.
84
0~255
Dimmer Brightness Level12 Data: Dimmer Level12 when less than this value.
91
0~255
Dimmer Brightness Level13 Data: Dimmer Level13 when less than this value.
98
0~255
Dimmer Brightness Level14 Data: Dimmer Level14 when less than this value.
105
0~255
Dimmer Brightness Level15 Data: Dimmer Level15 when less than this value.
4
1 ~ 16
Average count for Dimmer Brightness Data
-
0 ~ 255
Average Value for Dimmer Brightness Data * Read Only(8 bit)
-
0 ~ 15
Dimmer Level effective in auto-dimmer mode. 0 fixed other than auto mode (Read Only)
-
0 ~ 15
Dimmer Level effective other than auto-dimmer mode
72/74
30 ~ 100
Temperature A to judge the abnormal temperature, for surrounding temperature
55/58
30 ~ 100
Temperature B to judge the abnormal temperature, for Panels
71/73
30 ~ 100
Temperature C to judge the abnormal temperature, for Lamp
100
0 ~ 100
Temperature B-A to judge the abnormal temperature, for detecting clogged filter
100
0 ~ 100
Temperature C-A to judge the abnormal temperature, for detecting clogged filter
1
0 or 1
0: Auto Fan Control 1:Manual Control
135
0 ~ 255
Manual Adjustment Mode when FAN_CONTROL_SW=1
135
0 ~ 255
-
0 ~ 255
Fan Speed Monitor when FAN_CONTROL_SW=0, Read Only
-
0 ~ 255
-
-
Read Only
-
-
-
-
0
0 ~ 5
+15 degrees is added to Abnormal Temperature Value during x min after power on.
41/48
Control Start Temperature for FAN1 at Normal Mode
48/54
Control End Temperature for FAN1 at Normal Mode
41/48
0~255
Control Start Temperature for FAN2 at Normal Mode
48/54
Control End Temperature for FAN2 at Normal Mode
80/80
Minimum Control Value for FAN1 at Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
134/135
Maximum Control Value for FAN1 at Normal Mode
95/100
0~255
Minimum Control Value for FAN2 at Normal Mode
135/135
Maximum Control Value for FAN2 at Normal Mode
41/47
Control Start Temperature for FAN1 at Eco Mode
-10-
SVGA/XGA
SVGA/XGA
SVGA/XGA
SVGA/XGA
SVGA/XGA
SVGA/XGA
SVGA/XGA
SVGA/XGA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xu55

Table of Contents