O
S
II C
FF
HORE
LED I
Green
Red
Out
LED II
Red
Green blinking
Green
Out
• Do not operate the lamp immediately after the charging
M
C
AXIMUM
HARGING TIMES USING AN
DISCHARGED CELLS
Lamp Type
Voltage/ Capacity
125
12v / 5Ah
128
12v / 8Ah
HARGER
This charger utilises the latest in electronic charger
technology with a wide range input voltage (100v - 250v) with
frequencies of between 45 - 65 Hz. (There is no need to
manually select the input voltage).
All Hartenberger power packs with between 5 and 12 cells
will be automatically recognised by the charger, and charged
as fast as possible. The charging current can reach 2.0
amps.
The function of the charger is monitored via 2 light emitting
diodes (LED' s) with varying colours and flashes. The charger
is activated by plugging it into the mains supply.
Input voltage is present, the charger is functioning properly.
Input voltage is present, the charger is overloaded or
defective.
No input voltage present.
The charger cable should now be plugged into the charging
socket in the power pack. Do not use overdue force when
fitting the plug into the socket. Avoid any chance of short
circuiting the contacts of the plug or the power pack.
No Cells are connected (interruption).
Rapid charge up to approx. 95% of capacity.
Trickle charge with a reduced current.
Maintenance charge, Cells are fully charged.
All the functions of the charger are monitored by a controller
in the charger. This monitoring has a time lag when the
function of the charger changes, and may lead to a slight
delay in the LED' s reacting, (approx. 5 seconds).
The charger has an integrated mechanism protecting it
against overheating and large fluctuations in mains voltage.
(LED I turns red), Should the protection cut in, the charging
process will be interrupted. After the mains plug has been
removed from the mains socket for a few minutes, the
charger will then be ready for use again. Care must be taken
to achieve adequate cooling in extreme environments.
cycle is completed. Do not point the lamp at yourself or
in the direction of other persons.
O
-S
FF
HORE
Charger
LG Off-Shore II
LG Off-Shore II
11
Instructions for use
C
HARGER FOR FULLY
Charging
time
approx. 3 hrs
approx. 5 hrs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Professional

Table of Contents