MAINTENANCE SCHEDULE

Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspect/Clean Burner, Logs,
and Controls
Check Flame Patterns and Flame
Height
Inspect/Clean Pilot and Burner
Check Vent System
Appliance Checkout
Replace Glowing Embers
Periodically (After the Burning Season)
MAINTENANCE TASK
Clean Firebox Interior
Check Flame Patterns and Flame
Height
Check Vent System
Clean Front Glass Enclosure Panel
ACCOMPLISHING PERSON
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
ACCOMPLISHING PERSON
Homeowner
Homeowner
Homeowner
Homeowner
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs, and burner
area.
Refer to Figure 13 or Figure 14 on Page 20.Verify the flame pattern
and height displayed by the appliance conforms to the picture. Flames
must not impinge on the logs. Ensure flames are steady (not lifting or
floating).
Refer to Figure 15 on Page 20. Remove any surface build-up on the
pilot and burner assembly. Wipe the pilot nozzles, igniter/flame rod,
and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
or deterioration of the vent components.
NOTE: Excessive condensation can cause corrosion of caps, pipe
& fittings (excessive condensation can be caused by long lateral
runs, too many elbows, and/or exterior portions of the system being
exposed to cold weather). Also, inspect the wall straps or plumbers's
tape to ensure they are securely in place.
Perform the appropriate appliance checkout procedure detailed in this
manual.
Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers per instructions on Page 11.
PROCEDURE
Carefully remove logs, rockwool, and volcanic stone. Vacuum out
interior of the firebox. Clean firebox walls and log grate. Replace logs,
glowing embers (rockwool), and volcanic stone as detailed in this
manual.
Refer to Figure 13 and Figure 14 on Page 20. Verify the flame
pattern and height displayed by the appliance conforms to the picture.
Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components (reconnect or replace as necessary).
Clean as necessary following the directions provided in this manual.
Do not touch or attempt to clean glass while hot.