Raisecom Technology Co., Ltd. 1. Safety Notice Please read the following notice carefully before installing and using the device, Raisecom shall not be responsible for any loss that caused by violating safety notice. RC315/316-FE (Rev. A) has high sensitivity optical interface, so the power of optical transceiver output interface must be checked before connecting.
Raisecom Technology Co., Ltd. 2. Overview 2.1. Model Description RC315/RC316-FE series media converters include the following product articles: RC315-FE-S1, RC315-FE-S2, RC316-FE-S1, and RC316-FE-S2. Part Number Description RC315-FE-S1 Stand-alone, 10/100Mbps auto-sensing, single strand, single mode, 0-25km, RJ45/SC-PC RC315-FE-S2 Stand-alone, 10/100Mbps auto-sensing, single strand, single Mode, 10-50km, RJ45/SC-PC...
Raisecom Technology Co., Ltd. 4. Construction & Indicator 4.1. Front view and indicators 1. Front view of RC315/316-FE: O p tica l D a ta R J4 5 R J4 5 D a ta O p tica l R e ce ive...
Page 7
Raisecom Technology Co., Ltd. 2. Front view of 16-slot chassis 5V 12V 5V 12V RAISECOM Explanation of the indicators on 16-slot chassis is as follows: PWR indicator: ON, chassis power supply works normal. PS1-5V indicator: OFF, power supply PS1 for modules works normal, otherwise abnormal.
/MDIX auto-negotiation”, so both straight-through and crossover cables can be used to connect with other equipment. 2. When RJ45 interfaces of RC315/RC316 series media converters work in the forced status, the “MDI/MDIX auto-negotiation” function may fail. So it is suggested that the following connection types on the forced status adopted.
“Full Duplex Mode”. 5.3.2. RC315/RC316-FE Series RJ45 in Forced Status When RC315/RC316 series media converter is working in forced status, the RJ45 duplex mode configuration of other network equipment must complies with the following table, to ensure proper data transmission.
Raisecom Technology Co., Ltd. 6.5. Installation of DC Power Supply (for RC316) DC power supply provides three connectors: –48V, ground and 0V. These three connectors are connected respectively with –48V power cable, ground protection and 0V power cable. -48V 地 0V 6.6.
Raisecom Technology Co., Ltd. 7. DIP-switch Configuration RC315/316-FE series media converter has an 8-bit dip-switch SW4. The functions for each bit are as follows in sequence: auto-sensing enable/disable, bit-rate 100M/10M, full duplex/half duplex, vacant (reserved), fault-pass-through disable/enable, frame length 1916 bytes/1536 bytes, and module type configuration.
Raisecom Technology Co., Ltd. 8. Network Management 8.1. Card/Module Information Review With network management software, the status of RC315/316 series can be reviewed at the host site, and controlled/configured. The status information on “Show Module Info” is as follows: No. Status Name/Control & Configure Items Options Control &...
Page 14
Raisecom Technology Co., Ltd. @2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. -V36...