Beijing Raisecom Science & Technology Co., Ltd. 1. Safety Notice Please read the following notice carefully before installing and using the device, Raisecom shall not be responsible for any loss that caused by violating safety notice. RC513/514-FE (Rev. A) has high sensitivity optical interface, so the power of optical transceiver output interface must be checked before connecting.
Beijing Raisecom Science & Technology Co., Ltd. 2. Overview 2.1. Introduction RC513/514 series remote-end managed, bandwidth adjustable Ethernet media converters are new generation media converters developed by Raisecom. The remote-end management means that the network administrators can manage both the host-end and the remote-end equipments to conduct such operations as working status review, equipment control, loop-back test, and data flow statistics, etc.
Part Number Description Standalone, remote managed, 10/100Mbps auto-sensing, single mode, single strand, RC513-FE-S1 dual wavelengths, 0-25Km, RJ45/SC Module, remote managed, 10/100Mbps auto-sensing, single mode, single strand, dual RC514-FE-S1 wavelengths, 0-25Km, RJ45/SC Note: RC514-FE and RC513-FE must be deployed in pairs.
Beijing Raisecom Science & Technology Co., Ltd. 4. Construction & Indicator 4.1. Front view and indicators 4.1.1. The Indicators on the Front Panel Optical Data ETH Data Duplex mode Optical RX Link TX/RX Action /Collision TX/RX Action RMD 100M Remote...
Beijing Raisecom Science & Technology Co., Ltd. ON: Power supply works in good condition; Power Supply Power OFF: Power supply disconnected. 4.1.3. 16-Slot Chassis (for RC514) Front Panel Sketch 5V 12V 5V 12V RAISECOM The working conditions indicated by each indicator are as follows: PWR: steady ON, the power supply of chassis is working in good condition.
Media Converter Network Interface Card Crossover/Straight-through 2. When RJ45 interface of RC513/514 series media converters works on the forced status, the “auto MDI/MDIX crossover” function may fail. So it is advised to adopt the following connection modes in the forced status.
The same wavelength (single strand dual-wavelength media converters are not included) The same bit rate Matched optical power Fast Ethernet protocol (IEEE 802.3u Fast Ethernet) Note: when the fiber port of RC513/514 series media converters is connected with other equipment, the remote-end SNMP management does not work.
Beijing Raisecom Science & Technology Co., Ltd. 6.5. Installation of DC Power Supply (for RC514) DC power supply provides three connectors: –48V, ground and 0V. These three connectors are connected respectively with –48V power cable, ground protection and 0V power cable.
Beijing Raisecom Science & Technology Co., Ltd. 7. DIP-switch Configuration 7.1. Explanation for SW20 Setup SW20 switch has 8 bits and the functions for each bit are as follows in sequence: Auto-negotiation enable/disable, rate 100M/10M, full duplex/half duplex, reserved (vacant), frame length 1916 bytes/1536 bytes, remote network management enable/disable, reserved (vacant), Fault-pass-through disable/enable.
Beijing Raisecom Science & Technology Co., Ltd. 8. Network Management 8.1. Card/Module Information Review With network management software, the status of RC513/RC514 series can be reviewed at the host site, and controlled/configured. The status information on “Show Module Info” is as follows: No.
Beijing Raisecom Science & Technology Co., Ltd. command “Show Module Info. Loop-back”. The results of test can be shown through Show Module Info. 8.4. Show Module Info Reset The host or remote-end modules can be reset through “Host Module Reset”. The frame length after the reset is 1,916Bytes, and the working mode of port RJ45 is auto-negotiation.
Page 16
Beijing Raisecom Science & Technology Co., Ltd. @2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. -V36...