PILOT BURNER ADJUSTMENT

Remove the pilot screw cap. Adjust the pilot screw to pro-
vide properly sized flame. Turn in a clockwise direction to
reduce the gas flow. Replace the pilot screw cap.
FIGURE 46
FLAME MUST ENVELOP
UPPER 3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE
FIGURE 47

ADJUSTMENTS

THERMOPILE
THERMO-
COUPLE

VENTURI ADJUSTMENT

To access the venturi, remove the screw securing each
burner to the burner pan; slide to the right, lift up and out.
Natural gas and propane models have air shutters set at
3
/
(.188) inch open on the front burner. The rear burner air
16
shutter opening is set at ½ (.500) inch open. Closing the
air shutter will cause a more yellow flame, but can lead to
carboning. Opening the air shutter will cause a more blue
flame, but can cause flame lifting from the burner ports.
The flame may not appear yellow immediately; allow 15 to
30 minutes for the final flame colour to be established.
AIR SHUTTERS
FRONT BURNER
Air shutter adjustment
must only be done by a
qualified gas installer!
REAR BURNER
FIGURE 48
FIGURE 49