ROUTINE MAINTENANCE
* Inspect your stove at minimum frequency stated until you establish a minimum frequency required for your instal-
lation (frequency will vary depending upon fuel BTU value / ash content, usage, and misc. installation variables).
ROUTINE CLEANING
Note: Stove will need to be shut off and cooled enough to
handle before routine cleaning is performed. Always dis-
connect power before doing any routine cleaning.
The following areas need to be inspected during routine
cleaning:
•
UltraGrate (burn grate)
•
Ash Slide Plates
•
Ash Pan
•
Heat Exchange Tubes
•
Exhaust Passages and Vent Pipe
Maintenance Reference Diagram
Left Exhaust
Passage
Clean-out
Plate
Ash
UltraGrate
Slide
Plates
Grate Scraper /
Ash Slide
Ash Pan Tool
Plates
Exhaust
Right Exhaust
Passage Clean-
out Plate
ULTRAGRATE (BURN GRATE)
The UltraGrate should be inspected periodically to as-
sure that the air holes have not become clogged with ash
or clinkers. The UltraGrate can easily be cleaned with
the grate scraper / ash pan tool, or it can be removed for
cleaning. It is very important to monitor the ash build up
under the UltraGrate, as excessive amounts of ash will
block combustion air from entering the grate, causing
pellets to pile-up in the grate.
UltraGrate
Housing
Exhaust
Grate Scraper
* (Recommended Frequency of 1 day – 2 weeks)
Page 18
Cleaning UltraGrate
UltraGrate