Atx motherboard with 3.4ghz pentium 4 cpu, 5 pci and 2 pcie slots, vga, sata, raid, usb, lan, and audio (262 pages)
Summary of Contents for CyberResearch CPPC CEL-20-X
Page 1
® CPU Cards CPPC Series PICMG Single Board Computers CPPC CEL-20-X: 2.0GHz Celeron CPU CPPC CEL-28-X: 2.8GHz Celeron CPU CPPC P4-24-X: 2.4GHz Pentium 4 CPU CPPC P4-32-X: 3.2GHz Pentium 4 CPU USER’S MANUAL VER. A1 • DEC 2004 No part of this manual may be reproduced without permission ®...
Page 3
CyberResearch, Inc. In no event will CyberResearch, Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of or inability to use the product or documentation, even if advised of the possibility of such damages.
Page 9
® CyberResearch CPPC Series CPU Cards CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
2. Check the contents of the carton box: Single Board Computer Installation Guide Floppy ribbon cable ATA-66/100 HDD ribbon cable CD Driver Printer & COM1 ribbon cable CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
SATA Port1 SATA ISA BUS iTE Bridge SATA Port2 IT8888F Super I/O W83627HF Keyboard Mouse COM Port LPT Port Floppy Figure 2: System Block Diagram CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 17
Extended Function: - Hardware monitoring function - IrDA by pin-header Form Factor: - 13.3” x 4.8” (338 x 122mm) Weight: - 0.93lb (420g) --- CPPC CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Retention Module to hold up the weight of Heat Sink & Fan. Heat Sink & Fan Retention Module Installation (For P4 processor only) (For P4 Heat Sink & Fan) Figure 4: Heat Sink Installation CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
To move a jumper from one position to another, use needle-nose pliers or tweezers to pull the pin cap off the pin and move it to the desired position. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Jumper Location diagram. Clear CMOS setting select: JP1 Function Normal (Default) Clear CMOS Location: Watchdog Timer setting select: JP2 Function Reset System (Default) Location: CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
3.5 for the details. Advanced Chipset Features: Use this menu to change the values in the chipset registers and optimize your system's performance. See 3.6 for the details. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
IDE Channel 0 Master: Options are in its sub menu (described in 3.4) Press <Enter> to enter the sub menu of detailed options. IDE Channel 0 Slave: Options are in its sub menu (described in 3.4) CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 45
Displays the amount of conventional memory detected during boot up. Extended Memory: Displays the amount of extended memory detected during boot up. Total Memory: Displays the total memory available in the system. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 47
**** Warning: Setting a value of 65535 means no hard disk Landing zone: Options Min = 0, Max = 65535 Sector: Options Min = 0, Max = 255 Number of sectors per track CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
Page 49
Keystrokes repeat at a rate determined by the keyboard controller. When enabled, the typematic rate and typematic delay can be selected. The choice: Enabled, Disabled. Typematic Rate (Chars/Sec): CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
Page 51
____________________________ Menu Level Move Enter: Select +/-/PU/PD: Value F10: Save ESC: Exit F1: General Help F5: Previous Values F6: Fail-safe defaults F7: Optimized Defaults CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 53
The choice: 1, 2, 4, 8. Agent after boot: This item allows you to keep agent running after OS boot. The Choice: Enabled, Disabled. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 55
Selecting “Enabled” allows caching of the system BIOS ROM at F0000h-FFFFFh, resulting in better system performance. However, if any program writes to this memory area, a system error may result. The choice: Enabled, Disabled. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
If your IDE hard drive supports block mode (most new drives do), select Enabled for automatic detection of the optimal number of block read/writes per sector the drive can support. The choice: Enabled, Disabled CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
Page 59
This item allows you to decide to auto or disable the chipset family to support AC97 Audio. The choice: Auto, Disabled. CSA LAN(Giga-LAN): Enables the onboard LAN feature. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 61
PWRON After PWR-Fail: This item allows you to select if you want to power on the system after power failure. The choice: Off, On and Former-Sts. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
F6: Fail-safe defaults F7: Optimized Defaults ACPI Function: This item allows you to enable/disable the Advanced Configuration and Power Management (ACPI). The choice: Enabled, Disabled. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 65
The choice: Enabled, Disabled. Wake Up On Lan: An input signal from Lan awakens the system from a soft off state. The choice: Enabled, Disabled. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
It allows you can automatically configure all the boot and Plug and Play-compatible devices. If you select Auto, all the interrupt request (IRQ) and DMA assignment fields disappear, as the BIOS automatically assigns them. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
Show you the current CPU fan operating speed. Current System FAN Speed: Show you the current system fan operating speed. VDIMM: Show you the voltage level of the DRAM. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
The choice: Enabled, Disabled. Spread Spectrum: This item allows you to set the spread spectrum modulated. The choice: +/- 0.35%, +/- 0.50%, +/- 0.75%, +/- 1.0%, Disabled. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
“System”, the password will be required both at boot and at entry to Setup. If set to “Setup”, prompting only occurs when trying to enter Setup. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
Page 75
This allows you to exit Setup without storing in CMOS any change. The previous selections remain in effect. This exits the Setup utility and restarts your computer. CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
Page 77
Signal connections and programming are the two most common sources of difficulty. CyberResearch support personnel can help you solve these problems, especially if you are prepared for the call.
Page 79
CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
Need help?
Do you have a question about the CPPC CEL-20-X and is the answer not in the manual?
Questions and answers