Table Of Contents; Packaging; Introduction; Requirements - Lennox Hearth Products Crestline LSBV-3628EN Installation Instructions Manual

Crestline series b-vented gas appliances
Table of Contents

Advertisement

TABLE OF CONTENTS

Packaging ........................................ page
Introduction ..................................... page
Massachusetts and New York
Requirements ................................ page
General Information ......................... page
Location .......................................... page
Appliance Specifications .................. page
Clearances ....................................... page
Gas Vent Rule .................................. page
Framing Specifications .................... page
Assembly Steps ............................... page
Installation ....................................... page
Vent System Installation .................. page
Field Wiring ..................................... page
Connecting Gas Line ........................ page
Outside Air Kit Installation ............... page
Log and Rockwool Installation ........ page
Appliance Operation ........................ page 10
Manual Limit Switch ........................ page 10
Millivolt Appliance Checkout ............ page 11
Adjustments .................................... page 11
Finishing Requirements ................... page 12
Cold Climate Insulation .................... page 12
Installation Accessories ................... page 12
Gas Conversion Kits .................. page 14
This manual is part of a set of two supporting
this product. Refer to manual 875,035M for
Care & Operations.
Please read and understand these
instructions before beginning your
installation.

PACKAGING

The assembled vented gas fireplace is pack-
aged with:
1 - one foam packaged log set located in fire-
box area.
2 - one bag of glowing embers (rockwool)
located in the bottom compartment.
2
3 - one envelope containing the literature
package which consists of the homeowner's
2
manual, installation instructions, and war-
ranty; envelope is located in the control area.
2

INTRODUCTION

2
The millivolt appliances are designed to oper-
2
ate on either natural or propane gas. A millivolt
3
gas control valve with piezo ignition system
4
provides safe, efficient operation.
4
The electronic appliances are designed to op-
4
erate on either natural or propane gas. An
5
electronic intermittent pilot system provides
safe, efficient operation. External electrical
5
power is required to operate these units.
6
7
These appliances comply with National Safety
Standards and are tested and listed by Omni-
7
Test Laboratories (Report No. 116-F-45-5) to
8
ANSI Z21.50b (in Canada, CSA-2.22b), and
8
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplaces.
9
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.) Elec-
trical wiring must comply with local codes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)
These Crestline series appliances have been
designed, tested and listed for use with Security
Chimney's 10" B-vent system. Refer to page 12
for a complete listing of the 10" B-vent compo-
nents available for use with these models.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
Massachusetts And New York City, NY

Requirements

These appliances are approved for installation
in the following USA locations listed in the
following:
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Massachusetts:
Installation of these fireplaces are approved
for installation in the US state of Massachu-
setts if the following additional requirements
are met-
• Installation and repair must be done by a
plumber or gas fitter licensed in the Common-
wealth of Massachusetts.
• The flexible gas line connector used shall not
exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-
handle type valve.
New York City, NY:
Installation of these fireplaces are approved
for installation in New York City in the US state
of New York, if the following additional re-
quirements are met-
• An outside air kit (FOAK-4 or FOAK-4LD)
must be installed.

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instruc-
tions d'installation et d'utilisation qui
accompagnent l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
WARNING: THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.
These appliances are designed to operate on
natural or propane gas only. The use of other fuels
or combination of fuels will degrade the perfor-
mance of this system and may be dangerous.
Input of appliance are 45,000 BTU/HR for Pro-
pane models and 50,00 BTU/HR for Natural Gas
models.
Gas
Orifice Size
Type
Natural Propane
LSBV-3628
#26
#45
#26
#45
LSBV-4228
Elevation
0 - 4500'
(0 - 1370 m)
0 - 4500'
(0 - 1370 m)

Advertisement