TROUBLESHOOTING.

Manual Button does not work:
For the Manual switch to work there must be at least one successful temperature
transmission from the roof module after the unit is plugged in and switched on.
Transmissions require strong sunlight.
"00" in the display - no signal is being received.
There may be insufficient Sun. Or the distance between the transmitter and SunSwitch
may be too great [if so, then the transmitter must be moved closer.]
The 6-digit numbers don't match.
The two units may be mismatched or SunSwitch might be receiving signal from another
SunSwitch transmitter close by. Ring 1800 BATHER for a solution to this issue.
"01" is an internal fail-safe procedure.
If SunSwitch does not receive any transmissions for a set period of time it will institute a
count down from its current temperature down to "01" and switch the pump off.
Other Odd Numbers in the Screen:
If the roof transmitter has not sent a successful signal, the receiver will continue to
recall the last piece of information recorded on start-up or resetting. For example, the
last recorded roof temperature or signal strength may remain the same for hours until a
successful transmission has been received.

SERVICE FUNCTIONS:

Start-up Diagnostic: All lights, displays and non-volatile memory are checked on
start-up. "EE" will flash in the display if a fault is found.
Pool Sensor Fault Diagnosis: "Er" display indicates a faulty pool sensor. Cold
o
sensor is non-polar 4.7K Ohm at 25 C thermistor with these temp/resistance ohm
o
o
o
readings: 10 C - 9535, 20 C - 5902, 30 C - 3770, 40 C - 2480.
Electrical Specifications:
T on 6 C.
o
Readout Calibration: To fine tune the temperature readings hold TEMP SET button
down for 10 seconds until the display flashes. Pressing the up or down arrow buttons will
change the units base settings one degree each press. While in standby, the display reads
the last recorded temperature.
Service Lock-Out Mode: Hold AUTO & MAN buttons down for 10 seconds (LO
appears in display). Controller will remain in Lock-Out for 2 hours before reverting to
normal automatic operation.
o
T off at 2 C. Max relay overload 230V-10A
o
Sunbather Wireless SunSwitch
Operating Instructions.
Sunbather Pty Ltd
2174 Frankston-Flinders Road
PO Box 107 Hastings Victoria Australia 3915
T:03 5979 5777 F:03 5979 3577 E:info@sunbather.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wireless SunSwitch and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunbather Wireless SunSwitch

  • Page 1 Service Lock-Out Mode: Hold AUTO & MAN buttons down for 10 seconds (LO 2174 Frankston-Flinders Road appears in display). Controller will remain in Lock-Out for 2 hours before reverting to PO Box 107 Hastings Victoria Australia 3915 normal automatic operation. T:03 5979 5777 F:03 5979 3577 E:info@sunbather.com.au...
  • Page 2 SUNSWITCH INSTALLATION INSTRUCTIONS. Fix wall mounting bracket on a vertical wall protected from direct rain and sun. Step 1 Locate Roof Temperature Transmitter adjacent to the solar collector. Step 2 It must receive similar sun to the solar collector but not be in contact with it. Effective transmission range is up to 150 metres depending on surrounding buildings.
  • Page 3 SETTING UP THE WIRELESS LINK. Step I Ensure installation steps 1-5 have been completed and that the transmitter is in bright sunlight. Step II Hold the AUTO button down for 10 seconds until the alphanumeric display scrolls the SunSwitch serial number. This is 6 digit number. Step III Press the button once and the 6-digit Roof Transmitter serial number will appear if it is the same number you have successfully linked the transmitter to...
  • Page 4 ENERGY SAVING “ES” MODE: PRIMARY FUNCTIONS To Switch ON: When the Set Temperature has been reached, the letters “ES” and the pool Push the ON/OFF button once to switch the unit ON (pool temp reading will then display). temperature will alternate in the display. For Automatic Operation: This is not an error message - it indicates “Energy Saving Mode”...

Table of Contents