Download Print this page

Galaxy Audio DSPOT DS-EQ215 User Manual

Digital signal processor dual channel 15 band eq

Advertisement

Quick Links

DS-EQ215
USER'S MANUAL
PARAMETER
IN
®
DS-EQ215
OUT
EQUALIZER
ESCAPE
Dual Channel 15 Band EQ
USB
USB
19"
DIGITAL
DIGITAL
(482mm)

Advertisement

loading

Summary of Contents for Galaxy Audio DSPOT DS-EQ215

  • Page 1 DS-EQ215 USER’S MANUAL PARAMETER ® DS-EQ215 EQUALIZER ESCAPE Dual Channel 15 Band EQ 19" DIGITAL DIGITAL (482mm)
  • Page 3: Table Of Contents

    Introduction Introduction Thank you for choosing a Galaxy DSPOT Digital Signal Processor. You have joined hundreds of thousands of other satisfied Galaxy customers. Since 1977 Galaxy Audio’s professional experience in design and manufacturing ensure our products' quality, performance and reliability.
  • Page 4: Safety Instructions

    Safety Instructions Safety Instructions This symbol indicates that dangerous voltage This symbol indicates that there are important Constituting a risk of electric shock is present Operating and maintenance instructions in the within this unit. Literature Accompanying This Unit ! IMPORTANT SAFETY INSTRUCTIONS ! USE only with a cart, stand, tripod, bracket, or table READ these instructions.
  • Page 5: Getting Started With Front Panel Controls

    Overview Described below are the functions of the front panel control buttons and encoders for the DS-EQ215 Parametric Equalizer. PARAMETER ® DS-EQ215 EQUALIZER ESCAPE 1 - Input Level: Input Gain Left, Right 2 - EQ Bypass 3 - Output Level: Output Volume Left, Right 4 - LCD Display 5 - Clip LED: Process Overflow 6 - Parameter Key: Parameter Variation...
  • Page 6 Getting Started Using Front Panel Interface Brief description The DS-EQ215 is a graphic/parametric 2-channel EQ with 15+15 filters and channel link possibility. Its filters are symmetrical, and High/Low pass filters are included. A delay line for each channel is also available. Its settings are stored into 16 Factory and 16 User Presets. The device can also be linked to a controller using MIDI, RS232, or USB.
  • Page 7 To load the selected preset press ENTER. To leave sub-menu press QUIT. During preset loading, the display will show: Wait: Loading ..If the user tries to load an empty preset, a warning will be given: Error: Preset Empty SAVE PRESET MENU: Within this menu, use the NAVIGATION encoder to select the desired location between the user...
  • Page 8 Link : Are You Sure? Yes = Enter; No = Quit If confirmed, this command will wipe out Right channel settings, replaced by settings identical to the Left channel. Config Communication It is possible to select the remote control interface to use. Use the PARAMETER encoder to select one of the following: RS-232, USB, or MIDI Channel 1 through15.
  • Page 9 Flat Equ L/R This function resets all parametric filters of the Left/Right channel. After pressing ENTER, the following will be shown: Flat L: Are You Sure? Flat R: Are You Sure? Yes = Enter; No = Quit Yes = Enter; No = Quit Press ENTER to confirm, QUIT to cancel.
  • Page 10 Upon selecting H/L pass and pressing enter, the user accesses the menu: Left LP Filter Left LP Filter <F20.0> Order 1 <F20.0> Order 1 The NAVIGATION encoder selects Freq. Order. Left LP Filter Left LP Filter <F20.0> Order 1 F20.0 <...
  • Page 11: Using The Pc Interface

    Using the PC Interface Using the DS-EQ215 Software Load the Software “SetupDS-EQ215V1.0.0” either with the included CD or via the Galaxy Website. Double click on “Setup”, choose “Run” the software will load. Go to programs and double click on DS-EQ215V1.0.0 Connect the SDS-EQ215 with the USB cable to your computer.
  • Page 12 The software will look for active devices and show them in a list. To edit Double click on the desired device in the ID list. The Main Page will load.
  • Page 13 The device will also be locked out from front panel control at this point. You may choose to “Load Preset from PC”, “Save Preset to PC”, “Store Preset to Device”, “Read Preset from Device” From the main page you can choose the section you want to adjust by clicking on the associated block. Once you have accessed the block you can adjust parameters by either using the sliders, arrows, or typing the values in directly.
  • Page 14 Select the PEQ block to access the filter parameters. Select the Delay block to access the left and right delay parameters.
  • Page 15 Select the Limiter Block to access the left and right Limiter parameters.
  • Page 16: Midi Program Table

    MIDI Program Table Edit using the following steps: I. Be sure about the selected equalizer mode 2. Select the channel controller 0 3. Select the number of the filter controller 14 4. Change the amplitude of the selected filter controller 17 5.
  • Page 17: Specifications

    Specifications FUSE: REPLACE WITH 800mA SAME TYPE FUSE Inputs: 2 TRS Unbalanced Input Max Level: 9dBu Outputs: 2 TRS Unbalanced Output Max Level: 9dBu AID and DIA Resolution: 20 bit Process Resolution: 24x32 bit Processes: Equalizer Display: LCD 2x20 alphanumeric Connectivity: RS232/MIDI/USB SIN Ratio: >90 dBA (Bypass) THD+N: <0.01 % @ -6 dBFS (Bypass)
  • Page 20 Information can be viewed online at http://www.galaxyaudio.com/warranty.php DS-EQ215 Specifications in this manual are subject to change without notice. For the most up to date manual and information visit www.galaxyaudio.com. 1-800-369-7768 www.galaxyaudio.com © Copyright Galaxy Audio 2014 V02072014 Printed in China...