Kenwood KDC-CX89 Service Manual page 16

Kenwood cd auto changer service manual
Hide thumbs Also See for KDC-CX89:
Table of Contents

Advertisement

U
V
IC1
: UPC7805AHF
IC2
: LC72329-9274
IC4
: NJM78L05UA
IC101
: NJM2060M
1
IC102,302
: NJM4565MD
IC301
: BA1405F
Q1,3
: DTC124EK
Q2
: 2SA1782(T,U)
Q4,5,8
: DTC143TK
Q6
: DTA124EK
Q9
: 2SC4640(T,U)
Q101,201,304,305,308-310
: 2SK2158
Q303
: 2SA1162(GR)
Q306
: 2SK508L
Q307
: 2SC2714(Y)
2
14.4V
R1
F2 3A
ZD1
D2
RED
(ACC)
2.4K
ACC
+
14.4V
13.5V
3
R7
F1 3A
L1
D15
YEL
(BATT)
22 2W
+
+
+
BLK
(GND)
CN103
BU
13.5V
R8
22K
12.6V
Q2
13.4V
4
12.6V
C20
220u25
+
C114
0.015
6.3V
IC102
8
(1/2)
R109
C106
5
R116
1.8K
10u16
6.8K
6
+
7
6.3V
6.3V
6.3V
0V
4
R209
C206
2
1.8K
10u16
5
1
3
R216
+
6.3V
IC102
6.3V
6.8K
(2/2)
C214
0.015
R112
75K
C108
1000P
6
Q308
R343
100
C208
1000P
R212
75K
7
CAUTION: For continued safety, replace safety critical components only with manufacturer's recommended
parts (refer to parts list).
Indicates safety critical components. To reduce the risk of electric shock, leakage-
current or resistance measurements shall be carried out (exposed parts are acceptably insulated from the
supply circuit) before the appliance is returned to the customer.
W
X
RF MODULATOR UNIT
D1,5,14
: DSK10C-ET1
D2,15
: DSK10C-BT
D8,9,12,13,16 : 1SS131
D101,201,302 : DA204K
VD301
: HVU306A-3
ZD1-7
: MTZ6.2J(B)
SIGNAL LINE
GND LINE
+B
B LINE
(DATA IN)
8
7
6
(DATA OUT)
5
4
3
(LCD CE)
2
1
CN101
(LCD CLK)
0V
(GND)
3.5V
Q1
Q6
22K
22K
22K
22K
0V
Q4
Q5
1.1V
4.7K
4.7K
5.0V
IC1
IN
OUT
+5V
GND
+
BU
BU
R9
2.2K
D8
22K
Q3
22K
BU
+12.6V
+12.6V
6.3V
12.6V
R106 10K
6.3V
IC101
6.3V
4
C104
R105
12
10u16
IC101
(1/4)
R115
R114
10
10K
(2/4)
+
6.8K
6.8K
13
9
14
6.3V
8
11
R108
0V
R107
C105
6.3V
+
10K
10K
220u10
+
C205
R208
R207
220u10
+
10K
10K
6.3V
6.3V
6.3V
R214
6
R215
6.8K
7
R205
2
10K
C204
5
1
6.8K
10u16
IC101
3
(4/4)
6.3V
+
IC101
6.3V
R206
(3/4)
10K
+12.6V
+B
R328
C111
1u50
270
VR301
3.0V
R302 12K
+
33K(B)
4.3V
3.9V
R348
C306
R301
0V
3.1V
4.7u50
220K
220P
150K
IC301
0V
2.6V
3.5V
0V
3.5V
0V
0V
3.5V
+
Q101
2.1V
0V
Q201
C211
1u50
+
Y
Z
X302 4.5MHz
C11
R22
1K
22P
2.2V
1
0V
2
0V
3
R23
1K
0V
4
R25
5.0V
5
1K
0V
6
7
R26
1K
8
9
10
11
4.8V
12
12
5.0V
13
13
5.0V
14
14
4.8V
15
15
0V
16
16
5.0V
17
17
18
(CD RESET)
0V
19
5.0V
20
0V
21
0.6V
22
23
(+5V)
+5V
24
(D.GND)
BU
63
BU
BU
BU
R102
1.5K
BU
+12.6V
6.3V
IC302
(1/2)
3
1
2
D302
C312
+
6.3V
0.01
R202
6.3V
+
1.5K
+B
26
74
3.7V
61
Q303
C321
R337
C320
1u50
4.7K
180P
C335
R317
R319
+
2.4K
1.2K
R327 47K
+
R334
R325
4.7K
22K
+
+
Q310
Q304
Q305
Q309
•DC voltages are as measured with a high impedance voltmeter.
Values may vary slightly due to variations between individual
instruments or/and units.
AA
AB
+5V
C12
22P
5.0V
5.0V
67
64
XIN
COM2
3.0V
2.4V
63
4.6V
TEST2
P ON S1
63
2.8V
62
PG3
RELAY S2
62
61
0V
PG2
SEP ATT S3
61
60
0V
PG1
MUTE S4
60
59
PG0
ALC LOW S5
58
PH3
S6
57
PH2
S7
56
PH1
S8
55
PH0 MUTE1
S9
54
PF3 MUTE2
S10
IC2
17
53
PF2 REQC
S11
52
PF1 REQH
S12
51
PF0 CHCON
S13
CD
50
PE3 DATE IN
S14
49
PE2 DATE OUT
S15
12
48
PE1 SCK
S16
47
PE0
S17
46
16
PD3 DATE OUT
S18
45
PD2 CLK
S19
44
PD1 RST
S20
43
PD0 CE
S21
15
42
PC3
4.5V
S22
41
PC2
S23
13
0V
5.0V
0V
5.0V
14
+5V
+5V
R11
1K
+
BU
BU
BU
12.6V
5.7V
IC4
D14
Q9
4.9V
IN OUT
BU
13.5V
GND
+12.6V
R34
5.6V
12.6V
+
1.8K
RELAY
IC302
6.3V
8
R306
(2/2)
10K
5
+
6
R307
7
4.7K
4
R308
4.7K
150K
0V
C310
33P
R35
150
+B
R333 47
C332 5P
C324 15P
4.1V
0.9V
0.7V
4.8V
L305
C331
R338
L301
Q307
120nH
C322
C328
1P
4.7K
Q306
220nH
220P
2P
C325
0.01
C326
47u25
+
+5V
AC
AD
R14
3.3K
(SCK)
13
ZD2
ZD3
R15
R16
100K
3.3K
(REQ C)
9
ZD4
R17
1K
(DATA OUT) 11
ZD5
R18
R19
to CHANGER
100K
3.3K
(DATA IN)
10
CN102
ZD6
R20
1K
(REQ H)
1
1
5
9
ZD7
R21
E
2
6
10
4.7K
(CD POW)
4
13
3
7
11
4
8
12
(RESET)
7
(MUTE)
5
(D.GND)
2
+
(BATT)
3
BU
E
(Rch)
8
(S GND)
6
(Lch)
12
RL1
ANT IN
CN104
Q8
CN105
to RADIO
KDC-CMP59FM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-c719mpKdc-cmp59fmKdc-cps89mp

Table of Contents