Installation Instructions

Electrical Service

GENERAL
All wiring must conform to local, state and national
codes.
VOLTAGE
The maximum allowable voltage variation is ± 10%
of the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
The ice machines are factory pre-wired with a 6'
power cord only, no plug is supplied.
ECV ICE MACHINES
Ice Machine
ECV100

For United Kingdom Only

As the colours of the wires in the mains lead of the appliance may not correspond with
the coloured markings identifying the terminals in your plug, proceed as follows:
• The wire which is coloured green and yellow must be connected to the terminal in the
plug which is marked with the letter E or by the earth ground symbol
green or green and yellow.
• The wire coloured blue must be connected to the terminal which is marked with the
letter N or coloured black.
• The wire coloured brown must be connected to the terminal which is marked with the
letter L or coloured red.
2-4
WARNING
Voltage
Phase
Maximum
Cycle
Fuse/Circuit
Breaker
230/1/50
15
The ice machine must be grounded in accordance
with national and local electrical codes.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine. An electrical disconnect switch
must be provided if the ice machine is hard wired
(wired without a plug).
TOTAL CIRCUIT AMPACITY
The total circuit ampacity is used to help select the
wire size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it
must be determined by a qualified electrician.
Air-Cooled
Total Amps
4
Section 2
WARNING
Water Cooled
Maximum
Total Amps
Fuse/Circuit
Breaker
15