Junction Box Wiring Installation Instructions; Maintenance - White Mountain Hearth VFS32FB2DF-2 Installation Instructions And Owner's Manual

The breckenridge select vent-free universal fireboxes
Hide thumbs Also See for VFS32FB2DF-2:
Table of Contents

Advertisement

JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION,
MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES,
WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION)
A factory installed junction box is located on the lower right
hand side of the firebox. Wiring must be fed to the junction
box and attached to the receptacle that is provided. Remove the
knockout in the installed junction box to accept wiring into the
junction box. Install a UL listed cable clamp (not supplied) in the
knockout hole. Leave approximately 6" of wire in the junction
box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (neutral) screw.
Install the receptacle into the junction box. Attach cover plate.
Keep the control compartment, logs and burner area surrounding the
logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN
COOL.
Always turn off gas to the pilot before cleaning. For relighting,
refer to lighting instructions located on the log set.
INDEX
NO.
VFS32FB2DF
1
17247
2
10554
3
17162
4
R3492
5
R3491
6
19945
7
8
R8667
9
10
20020
11
R7051
12
R8213
13
19401
14
R9292
15
R9293
16
R9294
17
23004
Page 12

MAINTENANCE

PARTS LIST
PART NUMBER.
VFS32FB3DF
VFS32FB2EF
17247
17247
10554
10554
17162
17162
R3492
R3492
R3491
R3491
19945
19945
R8667
R9422
20020
20020
R7051
R7051
R8213
R8213
19401
19401
R9292
R9292
R9293
R9293
R9294
R9294
23004
23004
Never obstruct the flow of the combustion and ventilation air. Keep
the front of the firebox clear of all obstacles and materials.
Screens must be closed during operation.
VFS32FB3EF
DESCRIPTION
17247
TOP STANDOFF
10554
FRAMING BRACKET
17162
JUNCTION BOX ASSEMBLY
R3492
Receptacle
R3491
COVER, JUNCTION BOX
19945
BRACKET, TOP BRICK RETAINER
BRICK PANEL RIGHT
R9422
BRICK PANEL BACK
BRICK PANEL LEFT
20020
HOOD
R7051
ROD, SCREEN
R8213
SCREEN CURTAIN
19401
BRACKET, BOTTOM BRICK RETAINER
R9292
HEARTH LEDGE, RIGHT
R9293
HEARTH LEDGE, LEFT
R9294
HEARTH LEDGE, CENTER
23004
RETAINER, HEARTH LEDGE
Figure 20
23861-3-0808

Advertisement

Table of Contents
loading

Table of Contents