OPERATING HEATER
Continued
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, page 20.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow steps 9 through
11, Lighting Instructions, page 21.
OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be
purchased separately (see Accessories, page
31). Follow instructions included with the
remote control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 20.
1. After lighting, let pilot flame burn for
about one minute. Turn control knob to
ON position. Adjust flame adjustment knob
anywhere between HI and LO. Slide the
selector switch to the REMOTE position
(see Figure 31). Note: The burner may light
if hand-held remote was on when selector
switch was last turned off. You can now
turn the burner on and off with the hand-
held remote control unit.
IMPORTANT: Do not leave the selector
switch in the REMOTE or ON position
when the pilot is not lit. This will drain the
battery.
Control Knob
in On Position
Selector Toggle Switch
(Optional Remote Control)
Figure 31 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
22
Flame Adjustment Knob
ON
OFF
REMOTE
www.desatech.com
ON/OFF SERIES (MODEL HRC100)
Hold the control button on the hand-held
remote until burner turns on. Hold the con-
trol button again until burner turns off (see
Figure 34).
To Lock press both buttons on hand-held
remote control until light stops flashing. Hand-
held remote control is now locked. If the fire is
on it will be turned off automatically. In the
locked state, the light will not light up when
any button is pressed.
To Unlock press both buttons together on hand-
held remote control until the light stops flashing.
The hand-held remote is now unlocked.
Indicator
Light
Figure 32 - On/Off Hand-Held Remote
Control Unit (HRC100)
THERMOSTAT SERIES (MODEL
HRC200)
The hand-held remote can be operated using
either the manual mode (MANU) or thermo-
static mode (AUTO) (see Figure 35). To select
Fahrenheit/Centigrade mode display, carefully
press the ˚C/˚F mode button with the end of a
paper clip or similar blunt object.
Digital Display
Shows
Temperature
and Settings
Locks
System to
LOCK
Prevent
Accidental
Ignition
MANU
Turns
Burners
On or Off
Increases or Decreases Room
Temperature in AUTO Mode
Figure 33 - Thermostat Hand-Held
Remote Control Unit (HRC200)
Control
Button
Hand-Held
Remote On
AUTO
or Off and
ROOM
SET
TEMP
TEMP
Allows You
to Choose
TEMP
POWER
the Manual
AUTO
ºC/ºF
Selects
AUTO
Mode
°C/°F Mode
Button
112471-01B
Turns
Setting

Advertisement

Table of Contents
loading