h. Remove blanking panel, one (1) screw.
i. Remove side panel, one (1) screw.
j. Remove one (1) gas supply tube securing
screw and one (1) air intake tube securing
tube.
k. Rotate clip at end of gas supply tube and
push down on tube to release from
manifold.
l. Disengage gas supply tube.
m. Remove two (2) burner securing screws
and cable tie, to remove gas supply tube.
Energysaver RHFE-308 FTR
n. Remove flue spigot, three (3) screws.
o. Remove five (5) heat exchanger securing
screws.
p. Grip heat exchanger and pull forward to
remove.
Note: Refer section 5 f)~g) to disconnect burne
from heat exchanger complete assembly.
5)
Removal of Burner
CAUTION
240 volt potential exposure. Isolate the
applaince and reconfirm with a neon
screwdriver or multimeter.
a. Remove front panel assembly, see section
1.
b. Remove front heat shield, see section 4 b)
~ d).
c. Remove blanking panel, one (1) screw.
d. Remove spark sensing lead, and high
tension lead (pull off gently).
e. Remove one (1) gas supply tube securing
screw.
- 47 -
©Rinnai