1)
Removal of Front Panel
CAUTIO
240 volt potential inside applaince.
Disconnect electrical supply.
a. Grip sides of skirt and pull forward to
remove.
b. Remove seven (7) screws to release louvre
& front panel.
c. Grip bottom left and right hand corners of
front panel, pull forward to release.
Energysaver RHFE-308 FTR
2)
Removal of Top Panel, Control Panel,
and Control Panel PCB.
CAUTION
240 volt potential inside applaince.
Disconnect electrical supply.
a. Remove front panel assembly, see section
1.
b. Remove (2) two screws, one on each side of
control panel.
c. Release (3) three multi-pin connectors
from main PCB, releasing the control panel
PCB harness from wire clip on main PCB
casing.
d. Lift both sides of ocntrol panel and pull
forward to remove.
e. Grip control panel cover and lift up,
applying light strength on one side to
disconnect the hinge pin from control
assembly.
f. Unscrew seven (7) screws to remove
control PCB from control panel.