La Crosse Technology WS-7212U Instruction Manual

La Crosse Technology WS-7212U Instruction Manual

Wireless 433 mhz weather station
Hide thumbs Also See for WS-7212U:

Advertisement

WS-7212NU
Wireless 433 MHz
Weather Station
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for La Crosse Technology WS-7212U

  • Page 1 WS-7212NU Wireless 433 MHz Weather Station Instruction Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Topic Inventory of Contents Additional Equipment Quick Setup Guide Function Keys Detailed Set-up Guide Battery Installation Setting the Time Setting °C or °F Setting 12/24 Time Features Minimum and Maximum Temperatures Resetting Minimum and Maximum Temperatures Adding additional remote temp/humidity sensors (optional) Viewing &...
  • Page 3: Inventory Of Contents

    INVENTORY OF CONTENTS One indoor weather station (Figure 1) The remote temperature/humidity sensor (TX4U) and mounting bracket. (Figure 2) Mounting hardware. Instruction Manual and Warranty Card. Figure 1 Figure 2...
  • Page 4: Additional Equipment

    ADDITIONAL EQUIPMENT (not included) 1 Philips screwdriver. 2 Fresh AA 1.5V batteries. (for indoor weather station) 2 Fresh AA 1.5V batteries. (for temperature/humidity sensor)
  • Page 5: Quick Setup Guide

    QUICK SET-UP GUIDE Hint: Use good quality alkaline batteries and avoid rechargeable batteries. FUNCTION KEYS “SET”: Allows you to set the time, select °C or °F, and select 12 or 24 time display. “MIN/MAX”: Allows you to view the minimum and maximum temperatures recorded.
  • Page 6 MULTIPLE REMOTE SENSOR UNITS” section in the Detailed Set- Up Guide. Have the indoor weather station and remote temperature/humidity sensor 3 to 5 feet apart. Batteries should be out of all units for 15 minutes. Place the batteries into the remote temperature/humidity sensor first, then into the indoor weather station.
  • Page 7 temperature and humidity. If the indoor weather station does not display both the indoor temperature and the outdoor temperature and humidity after the 15 minutes please re-try the set-up as shown on page 5. After both indoor temperature and outdoor temperature and humidity are displayed for 15 minutes you can place your remote temperature/humidity sensor outdoors and set your time.
  • Page 8 reduce the distance of the range. An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of resistance. Your distance plus resistance should not exceed 330 feet in a straight line. To complete the set up of your indoor weather station after the 15 minutes have passed, please follow the steps...
  • Page 9 The hour will now be flashing. Press and release the “+” button until the correct hour is displayed. Press and release the SET button once more, and you are done. release the “SET” button once.
  • Page 10: Detailed Set-Up Guide

    DETAILED SET-UP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE/HUMIDITY SENSOR Battery compartment Remove the mounting bracket. Remove battery cover Observing the correct polarity, install 2 AA batteries—make sure they do not spring free, or start-up problems may occur. Replace cover. Battery cover...
  • Page 11 B. INDOOR WEATHER STATION Note: After the batteries are installed, DO NOT press any buttons for 15 minutes. This may interfere with the signal, causing temperatures to register incorrectly. Remove the battery cover on the backside. To do this, push up and pull out.
  • Page 12: Setting The Time

    The indoor weather station should now show: “-:- -” in the TIME LCD, indoor temperature in the INDOOR LCD and outdoor temperature and humidity in the OUTDOOR LCD. II. SETTING THE TIME Press and hold the “SET” button for 5 seconds. The minutes will begin to flash.
  • Page 13: Setting °C Or °F

    midnight. During the AM hours this area will be blank. III. °C OR °F TEMPERATURE SETTING Press and release the “+” button to change from °F (Fahrenheit-Default) to °C (Celsius). Press and the release the “SET” button to move to the 12/24 Hour Time Setting.
  • Page 14: Features

    FEATURES A. MINIMUM AND MAXIMUM TEMPERATURES Press and release the “MIN/MAX” button to toggle to the minimum temperatures, “MIN” appears at the bottom of the display and the recorded minimum temperatures are displayed. Press and release the “MIN/MAX” button, “MAX” appears at the bottom of the display and the recorded maximum temperatures are displayed.
  • Page 15: Adding Additional Remote

    ADDING ADDITIONAL REMOTE TEMPERATURE /HUMIDITY SENSORS (OPTIONAL) The WS-7212U is able to receive signals from 3 different remote temperature, temperature/humidity sensors. The following are some brief instructions for the basic set-up of remote sensor units with the WS- 7212U. These extra sensors can be...
  • Page 16 Note: When setting up multiple units it is important to remove the batteries from all existing units in operation, then to insert batteries first into all the remote temperature/humidity sensor units, and in numeric sequence. Second, install batteries into the indoor weather station. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6...
  • Page 17 remote sensors. Install batteries into the indoor weather stations. Follow the Detailed Set-Up Guide for programming and operating instructions. VIEWING AND OPERATING WITH MULTIPLE REMOTE SENSOR UNITS To view the temperature of a different remote sensor unit, press and release the “CH” button. A shift from one “boxed”...
  • Page 18: Mounting

    “boxed” number). Pressing and releasing the “MIN/MAX” button will toggle through the minimum and maximum indoor temperature, and the minimum and maximum outdoor temperature. To reset the Minimum/Maximum readings, press and hold the “MIN/MAX” button for 5 seconds. MOUNTING Note: To achieve a true temperature reading, avoid mounting in direct sunlight.
  • Page 19 A. REMOTE TEMPERATURE/ HUMIDITY SENSOR Remove the mounting bracket from the remote temperature/humidity sensor Mount using either screws or adhesive tape. Re-attach the remote temp/humidity sensor to the mounting bracket. B. THE WEATHER STATION The indoor weather station comes with the table stand already mounted.
  • Page 20: Troubleshooting

    Gently pull the indoor weather station down to lock the indoor weather station into place. TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.lacrossetechnology.com Problem: The LCD is faint Solution: Replace batteries Problem: No outdoor temperature or humidity is displayed.
  • Page 21 ten minutes and then check for a temperature and humidity. 2) If this does not work please remove the batteries from both units and restart the system (please see Detailed Set-up on page nine through eleven). Note: Please make sure when restarting the system that all batteries are fresh.
  • Page 22 4) If after 15 minutes the temperature and humidity are not displayed you will need to choose another location for placement of the temperature/humidity sensor. 5) The best way of doing this is to move the sensor 10 feet closer to the indoor weather station.
  • Page 23 working environments. The indoor sensor is less responsive to ambient air currents because of the shielding effect of the indoor weather station’s case. In addition, the casing can act as a heat sink to absorb and store heat from external sources (i.e. handling of the case or radiant heat).
  • Page 24: Maintenance And Care

    Do not submerge in water. • unnecessary heat or cold by placing them in the oven or freezer. • Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology for repairs. temperatures, subject vibration, units...
  • Page 25: Specifications

    SPECIFICATIONS Transmitting Frequency Measuring Range - Temperature Indoor Weather Station: Indoor Indoor Weather Station: Outdoor Temp accuracy Measuring Range - Humidity Indoor Weather Station: Temperature Checking Interval Indoor: Outdoor: Humidity Checking Interval Outdoor: Transmitting range: 433MHz 32°F to 138.2°F with 0.2°F resolution.
  • Page 26: Warranty Information

    Temperature /Humidity Sensor Battery life WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of 2 x AA, 1.5V 2 x AA, 1.5V 7.5”...
  • Page 27 La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above.
  • Page 28 Technology, Ltd will pay ground return shipping charges to the owner of the product to a USA address only. Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance);...
  • Page 29 Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or information contact: La Crosse Technology 2809 Losey Blvd. S. La Crosse, WI 54601 Phone: 608.782.1610 Fax: 608.796.1020 e-mail: support@lacrossetechnology.com...
  • Page 30 (2) this device must accept any interference received, including interference that cause undesired operation. Freq. 433.92 MHz La Crosse Technology Made in China WS-7212U FCC ID: OMO-01RX (Receiver) OMO-01TX (Transmitter) 082905 All rights reserved. This handbook must not be...

This manual is also suitable for:

Ws-7212nu