12-2. MUZ-EF50VE
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the top panel.
(6) Remove the valve cover.
(7) Disconnect the power supply and indoor/outdoor connect-
ing wire.
(8) Remove the screws of the cabinet.
(9) Remove the cabinet.
(10) Remove the screws of the back panel.
(11) Remove the back panel.
OBH590B
NOTE: Turn OFF power supply before disassembly.
Photo 1
Screws of the top panel
Screws
of the
cabinet
Screws of the
cabinet
Photo 2
Screws of the top panel
Screws
of the
cabinet
Screws of the
service panel
Screw of
the valve
cover
49
PHOTOS
Screws of the
cabinet
Screw of the back panel
Screws of the
cabinet
Screws of the
back panel