Refrigerant System Diagram - Mitsubishi Electric MUZ-EF25VE - E1 Service Manual

Split-type air conditioners outdoor unit
Table of Contents

Advertisement

7

REFRIGERANT SYSTEM DIAGRAM

MUZ-EF25VE MUZ-EF25VEH
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
OBH590B
4-way valve
Muffler
Stop valve
Discharge
temperature
thermistor
RT62
Capillary tube
ø3.0×ø2.0×240
Stop valve
(with strainar)
4-way valve
Muffler
Stop valve
Discharge
temperature
thermistor
RT62
Capillary tube
ø3.0×ø2.0×240
Stop valve
(with strainar)
Outdoor
Muffler
heat
exchanger
Compressor
Defrost
thermistor
RT61
LEV
Refrigerant flow in cooling
Refrigerant flow in heating
Muffler
Compressor
Defrost
thermistor
RT61
Capillary tube
ø3.0×ø1.8×600(×2)
LEV
Refrigerant flow in cooling
Refrigerant flow in heating
11
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Outdoor heat
exchanger
temperature
thermistor
Outdoor
RT68
heat
exchanger
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Unit: mm
Unit: mm