Baxi Bermuda SL3 Installation And Servicing Instrucnions page 14

Fireside gas central heating unit
Hide thumbs Also See for Bermuda SL3:
Table of Contents

Advertisement

Existing Fire – Page 15
The following spares components differ from Natural Gas
models.
Bermuda SL3 Propane
Click here for Helplines
Supplied By www.heating spares.co Tel. 0161 620 6677
Propane Cat II
2H3P
Supplementary Instructions
BERMUDA SL3 PROPANE
G.C.N0 3707770
GASTYPE G31
This section details the differences between Natural Gas and
Propane models.
Propane firefronts are only suitable for use with Bermuda
553 Propane Back Boiler appliances. The• instructions
supplied with the back boiler contain details of gas supply
requirements and electrical connections.
All site requirements and installation details can be found
earlier in this booklet.
NOTE: When removing the burner it is necessary to
remove the right hand retaining screw and the left hand
coal bed retaining pin which also retains the burner.
Propane appliances can be converted to operate on Natural
Gas if required. A conversion kit. is available, Baxi Part N'~
247065.