Existing Fire – Page 14
If the fire is wall mounted remove and discard the existing
support frame (Bermuda 401 only). Retain the two support
brackets. These will be needed in wall mounting the renewal
fire.
If the fire is hearth mounted ensure that the base of the
builders opening and the front hearth are at the same level.
Refer to "Site Requirements" (page 3) and prepare the wall
surface to the dimensions described.
WALL FIXING
Two wall fixing plates are supplied in the Renewal Kit, one
for Bermuda 401/552 and one for Bermuda 45/3, 57/3. 45/4
& 57/4.
BERMUDA 401 & 552
Take the fire support plate from the fire unit packaging
and loosely attach it beneath the boiler base protruding from
the fireplace opening using the M5 Nuts and screws
provided. Use the centre group of holes at each side.
NOTE: If the fire is being used with a Bermuda 401 boiler
unit, the support brackets from the previous plate must be
fitted before the fire support plate can be fixed in place.
Push the support plate backwards until it touches the
surround or wall face and tighten the screws to lock it in
position.
BERMUDA 45/3 & 57/3, 45/4 & 57/4
Take the fire support plate from the fire unit packaging and
loosely attach it above the boiler base protruding from the
fireplace opening using the screws provided. Use the slots at
each side.
Push the support plate backwards until it touches the
surround or wall face and tighten the screws to lock it in
position.
WIRING
When connecting the firefront wire to the plug on the boiler
base tray refer to page 3 of these instructions.
FIRE SUPPLY PIPE
Two fire supply pipes are supplied in the Renewal Kit, one
for Bermuda 401 & 552 and one for Bermuda 45/3 & 57/3,
45/4 & 57/4 The smaller (6mm) diameter one is for Bermuda
45/3 & 57/3, 45/4 & 57/4 installations.
TO CONTINUE FITTING THE FIREFRONT REFER TO THE
INSTALLATION CHAPTER OF THESE INSTRUCTIONS.
Supplied By www.heating spares.co Tel. 0161 620 6677