Download Print this page

Water Tec WS1TA Owner's Manual page 6

Water tec twin?alternating water softener

Advertisement

1) 
Connect second tank to main control valve. 
2) 
Connect Brine Tank  
3) 
Connect Drain 
4) 
Connect inlet & Outlet 
5) 
Program  Regenera on Capacity in gallons (see next page) 
**All  control programming with the excep on of the Regen Capacity is done at the factory.  
6) 
Perform a manual Backwash and rinse Cycle on each  tank. Press and hold REGEN bu on for 5 seconds to start a re‐
genera on  let the first backwash complete and then skip the   B rine & Rinse cycle by pressing the Regen bu on when  mer 
starts  coun ng down. Allow the next cycle to complete then skip the Fill Cycle for the first tank. Repeat these steps for the sec‐
ond tank ( DO NOT skip the fill cycle on the second tank).  
The system is now ready for use.  
***Do not remove red clips on Brine Tank connec on or Drain connec on, these clips are retainer clips and 
must be installed for proper opera on.  
Installa on and Startup 