Clearances - LG DLEX3570 Series Owner's Manual

Dryer lg dlex3570 series/ dlex3370 series/ dlex3170 series/ dlgx3571 series/ dlgx3371 series/ dlgx3171 series
Hide thumbs Also See for DLEX3570 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLAiTION
INSTRUCTIONS
]3
Insfallafion
Iocafion
requiremenfs
_WARNING
Read all installation
instructions
completely
before installing and operating
your dryer!
It is important
that
you review this entire manual before installing
and using your dryer. Detailed instructions
concerning
electrical
connections,
gas connections,
and exhaust requirements
are provided
on the following
pages.
. A location
that allows for proper exhaust installation,
A gas dryer must be exhausted
to the outdoors.
See
Venting the dryer,
• A grounded
electrical
outlet located within 2 ft.
(61 cm) of either side of the dryer. See Connecting
electric dryers.
. A sturdy floor to support
the total dryer weight of 200
Ibs (90.7 kg).The combined
weight of a companion
appliance
should also be considered.
. No other fuel-burning
appliance
can be installed in the
same closet as a dryer.
Do not operate your dryer at temperatures
below 45°F (7°C). At lower temperatures,
the dryer might not shut off
at the end of an automatic
cycle. This can result in longer drying times. The dryer must not be installed or stored in
an area where it will be exposed to water and/or weather. Check code requirements.
Some codes limit, or do not
permit,
installation
of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building
inspector.
"i_
NOTE
level floor with a maximum
slope of 1 inch (2,5 cm) under entire dryer. Clothes may not tumble
properly, and
utomatic
sensor cycles may not operate correctly
if dryer is not level.
or a garage installation,
you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a
pedestal, you will need 18 inches (46 cm) to the bottom
of the dryer.
Clearances
(2.5cm)(76.1cm)(12.Tcm)
(2.5cm)
(76.1cm) (12.7ci11)
3"
24in'_l_J_
_
1"_
_
27"-_
_ _1"
.o'._1
2.5_
66.6_
2.5_
h,_l_30,,_-15-*1
Cl_etDoorVent
_'
_"_tl _ 27" _'11÷_"
Requirements
(2.5 cm)
(68.6 cm)
(2.5 cm)
iNSTALLATiON SPACING FOR RECESSED AREA OR CLOSET iNSTALLATiON
The following
spacing dimensions
are recommended
for this dryer. Although
this dryer has been tested for
spacing of O inches (0 cm) clearance on the sides and rear, the recommended
spacing should be considered
for the
following
reasons:
• Additional
spacing should be considered
for ease of
installation
and servicing.
• Additional
clearances might be required for wall, door
and floor moldings.
. Additional
spacing should be considered
on all sides
of the dryer to reduce noise transfer.
For closet installation,
with a door, minimum
ventilation
openings
in the top and bottom
of the
door are required.
Louvered doors with equivalent
ventilation
openings
are acceptable.
. Companion
appliance
spacing should also be
considered.
Iia
NOTE
here should be at least a little space around the dryer (or any other appliance)
to eliminate
the transfer of
ibration from one to the other, With enough
vibration,
the appliances
will make noise or touch each other
using paint damage and making even more noise,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents