Installation Location Requirements; Clearances - LG DLGY2139EKD Series Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation Location Requirements

WARNING
you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical
connections, gas connections, and exhaust requirements are provided on the following pages.
gas dryer must be exhausted to the outdoors.
See
(61 cm) of either side of the dryer. See
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off
at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in
an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not
permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building
inspector.
NOTE
operate correctly if dryer is not level.

Clearances

21
1
/
"
4
(54 cm)
50
(127.5 cm)
INSTALLATION SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of
1 inch clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
installation and servicing.
and floor moldings.
NOTE
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of
vibration from one to the other. Too much vibration, it could cause them to make noise or touch each other
causing paint damage and making even more noise.
14" max.*
(35.6 cm)
3
40
/
"
16
(102 cm)
28
15
/
"
16
5"**
(73.4 cm)
(12.7 cm)
1
/
"
4
INSTALLATION INSTRUCTIONS
appliance should also be considered.
No other fuel-burning appliance can be installed in the
same closet as a dryer.
(2.54 cm)
(68.6 cm)
(2.54 cm)
of the dryer to reduce noise transfer.
For closet installation, with a door, minimum
ventilation openings in the top and bottom of the
door are required. Louvered doors with equivalent
ventilation openings are acceptable.
considered.
It is important that
(7.6 cm)
Closet Door Vent
(7.6 cm)
Requirements
13

Advertisement

Chapters

Table of Contents
loading

Table of Contents