MIN/MAX Adjustment and Factory Settings EXTENDED Menu Operation Overtemperature and Maintenance Specifications Copyright 2004-2008 Automation Correct LLC. All rights reserved. Coal-trol Digital™, Pelli-stat™ by Automation Correct LLC All others trademarks by the respective owners. SYRACUSE • NY Automation Correct LLC www.automationcorrect.com...
The Coal-trol Digital TS2 Thermostat features an LCD display, one LED indicator, and 3 pushbuttons for indication and control of all settings. User initiated fire start and fire stop controlled from the Thermostat. (Additional hardware required). Automation Correct LLC www.automationcorrect.com 5/2010 R0...
WARNING: BYPASS OF MECHANICAL VENT SPILLAGE SWITCH (FUME SWITCH) OR BONNET TEMPERATURE LIMIT, IF INSTALLED IS DANGEROUS. OPERATION MAY CAUSE SEROUS INJURY OR DEATH, DUE TO CO POISONING OR FIRE. FOR INDOOR USE ONLY. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
If a defect is found within three years from the date of original installation of the product (whether or not actual use begins on that date) Automation Correct LLC will provide a new or remanufactured part, at our sole option, to replace any defective part, without charge for the part itself.
Power to the Coal-trol system is controlled by the On/Off switch on the Control Module. When illuminated the control is on. Power to the thermostat is always on when the control module is plugged in and has power. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
UP button - Each press will increase a setting. Press and hold to increase fast. Also used to enable a selected setting. STATUS Light - When On indicates a startup, manual setting, or over temperature condition. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
Are all combustibles a safe distance from the Maintain SAFE appliance? Got working smoke alarm(s)? Got operation of my solid- working carbon monoxide detector(s)? Proper fuel appliance: draft? Regular appliance maintenance? Automation Correct LLC www.automationcorrect.com 5/2010 R0...
EXTENDED Menu Operations DAYTIME Setback See page 11 See page 13 NIGHTTIME Setback See page 9 In the documentation that follows, it is assumed that the Round-robin display is the 'Action' step starting point. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
ACTION Displays the fuel feed rate in Fr+ 13 Press MENU key 2 times. percent. (0-99%). If the display shows a plus sign (+), this indicates that the stoker motor is currently feeding fuel. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
In this example, at 11:30 PM the N 65F N 70F UP button thermostat will set the temperature to 65°F. DOWN button It can take an hour or more for the room temperature to move from one setting to another. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
Enable Igniter Features Advanced setting to enable Igniter IGN N IGN M UP button features. "N" for No, "M" for Manual. DOWN button Automation Correct LLC www.automationcorrect.com 5/2010 R0...
Set red nut to Set Feeder Set red nut adjustment tight against Mechanical Screw full to 5/8" from handle to acorn nut, then clockwise acorn nut. 11/16" from back off 2 turns. acorn nut Automation Correct LLC www.automationcorrect.com 5/2010 R0...
Auxiliary Fan Ignition Counter d e t e r m i n e i f t h e y a r e IC 000 working. Repeat at STOKER Automation Correct LLC www.automationcorrect.com 5/2010 R0...
1) Go to TEST mode and verify that the Stoker motor and Combustion 1) MAX set too high. Hot coals falling off of grate. blower are working properly. If not, 2) Control problem. replace Control Module. 2) Perform MAX/MIN adjustment. Automation Correct LLC www.automationcorrect.com 5/2010 R0...
Coal-trol Digital™ - Model TS2 V3 Page 15 Coal-trol Digital Specifications Note: Automation Correct LLC is constantly working to improve our products. For this reason, all specifications are subject to change without notice. Not all versions include all control options.
Automation Correct LLC designs and manufactures technology products for home and industry. Combining over 75 years of practical experience, the Engineers and Technicians of Automation Correct LLC are dedicated to supporting our customers with innovative products. Copyright 2004-2008 Automation Correct LLC. All rights reserved.
Need help?
Do you have a question about the Coal-trol Digital TS2 V3 and is the answer not in the manual?
Questions and answers