Anti Freeze & Freeze Protection
For Anti Freeze protection in the Quietside units the following products are
recommended
The maximum concentration allowed is 30% by volume which will protect the unit
down to approximately 5 DegF or -11 DegC
Water Quality
DPW models potable side must have the water quality within the following limits
for long life and reliable operation. The water supply should be tested to make
sure the quality is within specified limits. If there is a problem with the water
quality, contact your local water conditioning company for equipment to condition
the water supply to these appliances.
Operating this water heater with water conditions outside the specified limits will
void the warranty.
Description
PH
TDS
(Total
Dissolved
Solids)
Maximum
6.5 to 8.5
Up to
Levels
500 ppm
"No Burst"
"Fernox Alphii"
Total
Aluminum
Chlorides
Hardness
Up to
Up to
Up to
200 ppm
0.2 ppm
250 ppm
or 11.7
grains
hardness
70
Copper
Iron
Manganes
e
Up to
Up to
Up to
1.0ppm
0.3 ppm
0.05ppm
Zinc
Up to
5 ppm