Coolant Tank Preparation; Electrical Connections - Jet HVBS-7MW Operating Instructions And Parts Manual

Jet 7-inch horizontal-vertical band saw
Hide thumbs Also See for HVBS-7MW:
Table of Contents

Advertisement

Figure 3
Figure 4
Figure 5

6.5 Coolant tank preparation

Use of a water-soluble coolant will increase cutting
efficiency and prolong blade life. Do not use black
cutting oil as a substitute. Change cutting oil often
and follow manufacturer's instructions as to its
uses and precautions.
1. Disconnect machine from power source.
2. Remove coolant return hose from the tank
cover.
3. Slide tank out of saw base and carefully
remove the lid containing the coolant pump.
4. Fill tank to approximately 80% of capacity.
5. Place lid back onto tank, and place tank
assembly back into base.
6. Replace return hose back into the hole in the
tank lid.

6.6 Electrical connections

Electrical connections must
be
made
by
a
compliance with all relevant codes. This
machine must be properly grounded to help
prevent electrical shock and possible fatal
injury.
1. All Grounded, Cord-connected Tools:
In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric shock.
This tool is equipped with an electric cord having
an
equipment-grounding
grounding plug. The plug must be plugged into a
matching outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a
qualified electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
replacement of the electric cord or plug is
necessary,
do
not
grounding conductor to a live terminal.
electrician
or
service
grounding instructions are not completely
understood, or if in doubt as to whether the
tool is properly grounded. Failure to comply
may cause serious or fatal injury.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool's plug.
Repair
or
replace
immediately.
2. Grounded, cord-connected tools intended for
use on a supply circuit having a nominal rating less
than 150 volts:
This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in A, Figure
6. An adapter, shown in B and C, may be used to
connect this plug to a 2-pole receptacle as shown
in B if a properly grounded outlet is not available.
The temporary adapter should be used only until a
properly grounded outlet can be installed by a
qualified electrician. This adapter is not permitted
8
qualified
electrician
conductor
and
conductor.
If
repair
connect
the
equipment-
Check
with
a
qualified
personnel
if
damaged
or worn cord
in
a
or
the