HAAS + SOHN FIREPLACE INSERT General Instructions For Operation, Installation And Maintenance
HAAS + SOHN FIREPLACE INSERT General Instructions For Operation, Installation And Maintenance

HAAS + SOHN FIREPLACE INSERT General Instructions For Operation, Installation And Maintenance

Advertisement

Quick Links

General Instructions for Operation,
Installation and Maintenance
FIREPLACE INSERT
HAAS + SOHN Rukov s.r.o.
MANUFACTURER:
SNP 474, 408 01 RUMBURK, CZECH REPUBLIC
COMPANY ID: 62740989
TAX ID: CZ62740989
JK 06 185 16 04 14 09
d
CONTENTS
1.
TECHNICAL SPECIFICATIONS .............................................................................................4
1.1. General requirements on fireplace insert installations.............................................................4
1.2. Heating concept .......................................................................................................................4
1.3. Construction design .................................................................................................................5
2.
FIRING PROCESS ..................................................................................................................5
2.1. Fuel quantity and firing process adjustments ..........................................................................5
2.2. Fuel ..........................................................................................................................................6
3.
SAFE OPERATION .................................................................................................................6
3.1. General requirements ..............................................................................................................6
3.2. Safe distance between the fireplace insert and flammable material .......................................7
3.3. Safe distance between the smoke flue and flammable material .............................................7
3.4. Directions for safe operation ....................................................................................................7
4.
INSTALLATION AND CONNECTION TO THE CHIMNEY.....................................................7
4.1. Connection to the chimney or chimney insert .........................................................................7
Connecting the stove insert to the venting unit
4.2.
4.3. Directions for smoke flue installation and safety ....................................................................8
4.4. Installation of the fireplace insert within the room....................................................................8
4.5. Cleaning the heating device and chimney ...............................................................................9
Fire in the chimney
4.6.
................................................................................................................9
4.7. External combustion air supply ................................................................................................9
4.8
External air supply system .......................................................................................................9
5.
OPERATING INSTRUCTIONS................................................................................................9
5.1. Before first operation................................................................................................................9
5.2. Setting the fire ........................................................................................................................10
5.3. Feeding the fire .....................................................................................................................10
5.4. Glass cleanness .....................................................................................................................11
5.5. Operation during temporary period and at worsened weather conditions.............................11
5.6. Fireplace insert function adjustment ......................................................................................11
5.7. Ash removal ...........................................................................................................................11
6.
CLEANING AND MAINTENANCE........................................................................................12
6.1. Cleaning .................................................................................................................................12
6.2. Sealing lines and tapes ..........................................................................................................12
6.3. Spare parts.............................................................................................................................12
7.
WHAT TO DO IF... DO YOU DO IT YOURSELF?...........................................................13-14
8.
FREQUENT PROBLEMS AND QUESTIONS ......................................................................14
8.1. Cracked (released) fireclay (vermiculite) brick in the burning area .......................................14
8.2. Broken glass...........................................................................................................................14
8.3. Partitions to control the chimney effect ..................................................................................14
8.4. Blind element substituted with exchanger (optional) .............................................................15
9.
PRODUCT LIABILITY AND SERVICE .................................................................................15
9.1. General...................................................................................................................................15
9.2. Conditions for guarantee........................................................................................................15
9.3. Guarantee and post-guarantee service................................ .................................................15
9.4. Claim rejected ........................................................................................................................15
9.5. How to make a claim..............................................................................................................15
9.6. How to order spare parts........................................................................................................16
10.
MISCELLANEOUS ................................................................................................................16
10.1. Accessories supplied with the insert ......................................................................................16
10.2. Special accessories (on order)...............................................................................................16
10.3. Recommended spare parts....................................................................................................16
10.4. Package and waste disposal..................................................................................................16
10.5. ES Declaration of Conformity and CE Certificate ................................................................17
...................................................................8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIREPLACE INSERT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HAAS + SOHN FIREPLACE INSERT

  • Page 1 SAFE OPERATION .........................6 FIREPLACE INSERT 3.1. General requirements ......................6 3.2. Safe distance between the fireplace insert and flammable material ........7 3.3. Safe distance between the smoke flue and flammable material ..........7 HAAS + SOHN Rukov s.r.o. 3.4. Directions for safe operation ....................7 INSTALLATION AND CONNECTION TO THE CHIMNEY.............7...
  • Page 2: Technical Specifications

    Fireplace inserts are designed for heating in habitable rooms, recreation buildings, work stations and other places to provide thermal comfort. A fireplace insert is used as a closed fireplace while the visual effect - the perception connected with flame - is similar to the sensation of live fire. In comparison with conventional open fireplace, the insert is characteristic with higher thermic efficiency.
  • Page 3: Safe Operation

    • Any time you set the fire, let the primary air regulator open long enough to allow the fuel The fireplace insert may be a single- or twin-shell model. The twin-shell type is designed to provide burning properly. direct support to the convective stream flowing through the outer construction of the insert body. The •...
  • Page 4: Safe Distance Between The Fireplace Insert And Flammable Material

    (depending on the particular weight), Chart 3 including the weight of the casing. It is recommend to contact a statics specialist. The fireplace insert must be installed on a heat insulating base that overlaps the stove ground plan dimensions on the 4.
  • Page 5: Cleaning The Heating Device And Chimney

    For the very first fire, use smaller quantity of wood, maintaining the Further, approach in the chimney for occasional cleaning is required as well.
  • Page 6: Cleaning And Maintenance

    6.1. Cleaning least – on the way how the fireplace insert is operated. It is recommended to load one layer of the The fireplace insert (cold) needs cleaning at least once a year (after the season), or twice or more ( wood only: the logs should be laid evenly, farther from the glass (as far as possible).
  • Page 7: Frequent Problems And Questions

    Fireplace insert is operated in a Heating device adjustment is not optimal, see 2.1. Caution! Some types of the fireplace insert are not provided with the sealing tape along the whole wrong manner perimeter.
  • Page 8: General

    You can order spare parts and accessories at your local distributor – dealer, or at our partner organisation. 9.2. Conditions for guarantee The guarantee covers free-of-charge repair of the fireplace insert or parts or components (the 10. MISCELLANEOUS subject of complaint, if any) providing that the cause of the defect is defective material or craftsmanship.
  • Page 9 CE Certificate are in accord with Directive 89/106/EHS, issued by a notified body. Notified testing institutes (verification of the products manufactured by HAAS + SOHN: Strojírenský zkušební ústav, s. p. (Testing Institute of Engineering) ,ES 1015, AO 202, Hudcova 56 b, 621 00 Brno, Czech Republic.
  • Page 10 EXAMPLE: PROTECTIVE BARRIER PASSAGE THROUGH THE FIRE FOR THE HEATING DEVICE AND SMOKE PROOF SMOKE FLUE WALL FLUE (dimensions in mm) (dimensions in mm) 1 – Wall 2 – Smoke flue system 3 – Cover (fireproof, non-metal) 1 – Protective barrier for the heating device and smoke flue 4 –...