Rasmussen K18-C1C-M-N Assembly, Installation And Operation Instructions

Advertisement

A s s e m b l y , I n s t a l l a t i o n , a n d O p e r a t i o n
Instructions for Rasmussen "Single Burner"
Natural and Propane Gas Log Room Heater Models:
18" or 24" SINGLE BURNER Manual Control (K,W,KW)(18, 24)-C1A,C-M-(N,P)
30" SINGLE BURNER Manual Control (K,W,KW)(30)-C1B,D-M-(N,P)
18", 24" or 30" DOUBLE FACE Manual Control DF(K,W,C)(18,24,30)-DFC1,C1C-M-(N,P)
18" or 24" SINGLE BURNER Switch Control (K,W,KW)(18, 24)-C1A,C-S-(N,P)
30" SINGLE BURNER Switch Control (K,W,KW)(30)-C1B,D-S-(N,P)
18", 24" or 30" DOUBLE FACE Switch Control DF(K,W,C)(18, 24, 30)-DFC1,C1C-S-(N,P)
30" SINGLE BURNER Remote Control (K,W,KW)(30)-C1B,D-R-(N,P)
18" or 24" SINGLE BURNER Remote Control (K,W,KW)(18, 24)-C1A,C-R-(N,P)
18", 24" or 30" DOUBLE FACE Remote Control DF(K,W,C)(18, 24, 30)-DFC1,C1C-R-(N,P)
Read these Instructions carefully and retain them for future use.
THESE GAS LOG HEATERS ARE CERTIFIED TO THE FOLLOWING STANDARDS:
UNVENTED ROOM HEATER ANSI Z21.11.2a 2001
VENTED DECORATIVE APPLIANCE ANSI Z21.60b 2001 * CGA 2.26b-2001
Design certified for installation only in a solid-fuel burning masonry or UL 127 factory-built fireplace or
DO NOT install this appliance in a factory-built fireplace that includes instructions stating it has not been
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result
WARNING:
Improper installation,
alteration, service or maintenance can cause
property damage, personal injury or loss of life. Read
these instructions thoroughly before installation.
For assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
INSTALLATION AND SERVICE: Installation and service must be performed by a
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION
AIR" (pages 4 and 5.)
AGA "CHILLBUSTER I"
Manual, Switch, or Remote
in a listed ventless firebox enclosure.
tested or should not be used with unvented gas logs.
causing property damage, personal injury or loss of life
adjustment,
liquids in the vicinity of this or any other appliance.
qualified installer, service agency or the gas supplier.
.
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718
E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier,
call the fire department.
1
FAX (562) 698-3510
.
.
.
CB-1 2-03

Advertisement

Table of Contents
loading

Summary of Contents for Rasmussen K18-C1C-M-N

  • Page 1 A s s e m b l y , I n s t a l l a t i o n , a n d O p e r a t i o n Instructions for Rasmussen "Single Burner" Manual, Switch, or Remote Natural and Propane Gas Log Room Heater Models: 18"...
  • Page 2: Important Notice

    ALL APPLICATIONS (VENTED and VENT FREE OPERATION) IMPORTANT NOTICE • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
  • Page 3: Important Safeguards

    ALL APPLICATIONS (VENTED and VENT FREE OPERATION) 9. The CHILLBUSTER and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The CHILLBUSTER must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
  • Page 4: Provisions For Adequate Combustion And Ventilation Air

    VENT FREE OPERATION PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR This heater shall not be installed in a "confined" space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Confined Or Unconfined Space Determination: The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m per kW) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m...
  • Page 5: Minimum Clearances To Combustibles

    VENT FREE OPERATION COMBUSTION AIR CALCULATIONS WORKSHEET H=Vol. (ft 3 ) 1 . Room Width Length Height 1 a . 1 b . 1 c . 1 d . 2 . Total Volume (ft 3 )sum of Volume (ft 3 ) of all rooms (sum lines 1a.
  • Page 6 VENT FREE OPERATION FIREPLACE HOODS A fireplace hood deflects heat away from the fireplace face and mantel, reducing the potential for heat related warping or discoloration. The use of a fireplace hood is highly recommended. Fireplace Hoods are offered by many leading fireplace manufacturers.
  • Page 7: Log Placement

    ALL APPLICATIONS (VENTED and VENT FREE OPERATION) LOG PLACEMENT C1A, C1C, C1B, and C1D 1. 18" sets have 5 logs. 24" sets have six logs. 2. Place largest log (FRONT LOG) in the front of the grate and the second largest log (REAR LOG) on the rear of the grate behind the LOCATOR PINS.
  • Page 8: Lighting And Operation

    Pilot remains lit when knob is released. Manufactured by: 5. Slowly turn knob to “ON ”. The rear burner will light from the pilot. The Rasmussen front burner will light from the carry-over tube. Whittier, CA USA If appliance fails to light or if pilot goes out, repeat steps 1 through 5 .
  • Page 9 ALL APPLICATIONS (VENTED and VENT FREE OPERATION) Millivolt Pilot Lighting (continued): 6. Press Piezo Ignitor Button to PILOT ADJUST Figure 12 COVER CAP light pilot. Continue to hold in the Gas Cock Dial until the Pilot flame remains lit when knob is released PILOT (approximately 60 to 90 seconds).
  • Page 10 Additionally, firebox walls and damper must also be thoroughly cleaned of all burn residue and soot using a damp cloth, sponge or brush. • Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically designed and approved for use with this Burner System.
  • Page 11 4. The name of the part and part number from parts list. INSTALLED BY: Save these instructions GAS TYPE: Manufactured By: RASMUSSEN IRON WORKS, INC. 12028 E. Philadelphia Street DEALER: Whittier, California 90601 PARTS LIST C1A/C, C1B/D and DFC1/C1C (Manual, Switch or Remote)
  • Page 12 Gas Log Set and accessories against defects in above. materials and workmanship, and suitable for a particular (2) RASMUSSEN shall not be liable for any loss, purpose, for a period of: damage, incidental or consequential damages of any kind, whether based upon warranty, contract, or...
  • Page 13 CPW-CB-2-96 CHANGES (next) page 1: standard update z21.11.2a 2001 DUE 4-03; standard update z21.11.2b 2002 DUE 12-03...

Table of Contents