Instructions for Rasmussen Chillbuster "Evening Embers"
(C-7 or DFC-7) Manual , Switch or Remote Control, Natural and Propane
18", 24" or 30" SINGLE BURNER Manual Control (HG) (18, 24, 30) - C7-M- (N,P)
18", 24" or 30" SINGLE BURNER Switch Control (HG) (18, 24, 30) - C7-S- (N,P)
18", 24" or 30" SINGLE BURNER Remote Control (HG) (18, 24, 30) - C7-R- (N,P)
18", 24" or 30" SINGLE BURNER Manual Control (HH) (18, 24, 30) - DFC7- M-(N,P)
18", 24" or 30" SINGLE BURNER Switch Control (HH)( 18, 24, 30) - DFC7- S-(N,P)
18", 24" or 30" SINGLE BURNER Remote Control (HH)( 18, 24, 30) - DFC7- R-(N,P)
THESE GAS LOG HEATERS ARE CERTIFIED TO THE FOLLOWING STANDARDS:
UNVENTED ROOM HEATER ANSI Z21.11.2a 2001
VENTED DECORATIVE APPLIANCE ANSI Z21.60b 2001 * CGA 2.26b-2001
Read these Instructions carefully and retain them for future use.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury or loss of life. Read these instructions thoroughly
before installation. For assistance or additional information, consult your gas log dealer,
Design certified for installation only in a solid-fuel burning masonry or UL 127 factory-built fireplace or
in a listed ventless firebox enclosure. DO NOT install this appliance in a factory-built fireplace that
includes instructions stating it has not been tested or should not be used with unvented gas logs.
Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters, bathrooms or
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life
This appliance may be installed in an after
market,
permanently
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer, service
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION
AIR" (pages 4 and 5.)
"CHILLBUSTER 7"
E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com
Gas Log Room Heater Models:
qualified installer, service agency or gas supplier.
recreational vehicles.
located,
agency or the gas supplier.
.
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
1
FAX (562) 698-3510
.
.
FORM C7-2-03
.

Advertisement

loading

Summary of Contents for Rasmussen CHILLBUSTER Evening Embers 7 Series

  • Page 1 (562) 696-8718 FAX (562) 698-3510 E-Mail: gaslogs@riwinc.com Web http://www.riwinc.com Instructions for Rasmussen Chillbuster "Evening Embers" (C-7 or DFC-7) Manual , Switch or Remote Control, Natural and Propane Gas Log Room Heater Models: 18", 24" or 30" SINGLE BURNER Manual Control (HG) (18, 24, 30) - C7-M- (N,P) 18", 24"...
  • Page 2 ALL APPLICATIONS (Installation) ALL APPLICATIONS-IMPORTANT NOTICE • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room with the appliance. •...
  • Page 3 ALL APPLICATIONS (Installation) Fireplace/Firebox Sizing (VENTED and VENT-FREE): 1. The minimum size (in inches) of the fireplace in which this CHILLBUSTER is to be installed must be as follows: S E T MODEL FRONT SIZE NUMBER WIDTH HEIGHT D E P T H (HG)(18)-C7-(M,S,R)-(N,P) (20,000;...
  • Page 4 VENT-FREE APPLICATIONS (Additional Requirements) 1. Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters, bathrooms or recreational vehicles. 2. When operated as a VENT FREE heater, the minimum clearances from the fireplace opening to combustible materials must be maintained as outlined in section "CLEARANCES TO COMBUSTIBLES" (page 6). 3.
  • Page 5 VENT-FREE APPLICATIONS (Additional Requirements) COMBUSTION AIR CALCULATIONS WORKSHEET H=Vol. (ft 3 ) 1 . Room Width Length Height 1 a . 1 b . 1 c . 1 d . 2 . Total Volume (ft 3 )sum of Volume (ft 3 ) of all rooms (sum lines 1a.
  • Page 6 VENT-FREE APPLICATIONS (Additional Requirements) Fireplace Hoods (VENT-FREE) A fireplace hood deflects heat away from the fireplace face and mantel, reducing the potential for heat related warping or discoloration. The use of a fireplace hood is highly recommended. Fireplace Hoods are offered by many leading fireplace manufacturers.
  • Page 7: Lighting And Operation

    ALL APPLICATIONS (VENTED and VENT FREE OPERATION) Log Placement (cont.) Rear Bracket REAR LOG FRONT LOG (2) Pilot Burner Ember Ember Lifter Lifter Pilot Pilot Pilot FRONT LOG (1) Burner DFC7 EMBER MATERIAL: With the FRONT and REAR LOGS on the Grate as shown, pull apart the EMBER MATERIAL into long loose, thin pieces and drape Ember Burner...
  • Page 8 ALL APPLICATIONS (VENTED and VENT FREE OPERATION) C7-M or DFC7-M (MANUAL CONTROL) LIGHTING and OPERATION Pilot Lighting: BOOST 1. Push in Valve Knob and turn completely clockwise to “O F F”. Figures 5 and 6 NORMAL 2. Wait five minutes before lighting. AT PILOT POSITION 3.
  • Page 9 ALL APPLICATIONS (VENTED and VENT FREE OPERATION) Ultrasonic Remote Control (Manual or Remote ON-OFF) Manual: Switch from OFF to SWITCH ON; Before you start: Both the transmitter and receiver require 9 volt SWITCH ON to OFF batteries to operate in remote control. Remote: Switch to The blue and black receiver wire leads are for the optional sound producing REMOTE ACCESS...
  • Page 10: Normal Operating Characteristics

    Additionally, firebox walls and damper must also be thoroughly cleaned of all burn residue and soot using a damp cloth, sponge or brush. • Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically designed and approved for use with this Burner System.
  • Page 11 3. Type of gas (natural or propane Gas). 4. The name of the part and part number from parts list. INSTALLED BY: Save these instructions GAS TYPE: Manufactured By: RASMUSSEN IRON WORKS, INC. 12028 E. Philadelphia Street DEALER: Whittier, California 90601 PARTS LIST C7/DFC7-M/S/R (MANUAL/SWITCH/REMOTE)-N/P (NATURAL/PROPANE)
  • Page 12 Gas Log Set and accessories against defects in above. materials and workmanship, and suitable for a particular (2) RASMUSSEN shall not be liable for any loss, purpose, for a period of: damage, incidental or consequential damages of any kind, whether based upon warranty, contract, or...
  • Page 13 CHANGES (next) Consolidate C7 and DFC7 page 1: standard update z21.11.2a 2001 DUE 4-03; standard update z21.11.2b 2002 DUE 12-03 Title change: Customer Responsibilities And Annual Maintenance page 10...