GreenGLo 180S User Manual

Greenglo mains pressure integrated water heater single coil series & double coil series greenglo saver

Advertisement

Quick Links

USER MANUAL

INSTALLATION INSTRUCTIONS

WARRANTY REGISTER
GREENGLO MAINS PRESSURE INTEGRATED WATER HEATER
SINGLE COIL SERIES & DOUBLE COIL SERIES
GREENGLO SAVER
Customer
Congratulations for choosing a GreenGlo integrated water heater
We recommend you read page 1 to 5 of this manual.
It may save you time and trouble later.
Please register the product warranty as per page 20 of this manual
The other pages of the manual are intended for the installer.
For a further assistance or information contact our service desk
0800 447 336
info@greenglo.co.nz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 180S and is the answer not in the manual?

Questions and answers

Summary of Contents for GreenGLo 180S

  • Page 1: Installation Instructions

    SINGLE COIL SERIES & DOUBLE COIL SERIES GREENGLO SAVER Customer Congratulations for choosing a GreenGlo integrated water heater We recommend you read page 1 to 5 of this manual. It may save you time and trouble later. Please register the product warranty as per page 20 of this manual The other pages of the manual are intended for the installer.
  • Page 2 The information contained in this manual, and all other information or advice provided by GreenGlo Limited in connection with the purchase, installation use and service of GreenGlo water heater is given in good faith. GreenGlo Limited will not be liable for any person for any inaccuracy or omission in the information arising through the fault of GreenGlo Limited directly or indirectly.
  • Page 3: About Your Water Heater

    Do not remove covers unless essential and only after receiving specific instructions from GreenGlo service desk 7. GreenGlo is an indoor tank and shall be install in a well vented space to prevent condensation 8. There is a choice of double or single or double coil GreenGlo depending on the application needed.
  • Page 4: Product Information

    All GreenGlo models have a soft blanket cover for extra insulation GreenGlo Saver Setup and usage instructions of the GreenGlo Saver controller are available with the controller instructions book provided with the product. The controller is pre-wired and therefore no special installation instructions are necessary.
  • Page 5 45°R 45°R 45°R 45°R 45°R 45°R 45°R 90°R 90°R Max energy Bottom (kW) coil 17.5 17.5 20.0 24.6 39.3 35.0 37.2 Max energy upper (kW) coil 13.6 26.2 30.0 39.3 54.0 70.0 89.3 (kG) Weight © GreenGlo Limited Version 05/2010...
  • Page 6: Water Quality

    WATER QUALITY GreenGlo water heaters have been manufactured to deal with most local body water supplies. Desired water quality levels: pH Level between 6.5 and 8.5 Chlorides: up to 200 ppm Total Dissolved Solids (TDS) up to 1000 mg/L Saturation Index between -0.8 and +0.8...
  • Page 7: Plumbing Connection

    • the upper and lower dome prior to installation Basic Plumbing connection of the Water heater The size of the GreenGlo tank needs to be chosen carefully in order to • maintain the hot water supply demand. Start with the Basic Diagram of page 7 before conducting any specific •...
  • Page 8 The above diagram describes valves for a mains pressure arrangement; however the cylinder could also be fitted to a low pressure system. GreenGlo tanks are equipped with a service circulation port. Use this port for ring main or other external applications.
  • Page 9 Important Notes: 1. No valves or restrictions are allowed on the wetback loop 2. When installing Wetback and Solar using GreenGlo D Series, connect wetback to upper coil and solar to bottom coil. Wetback should be installed to the bottom coil with all other multiple connections 3.
  • Page 10 Follow the specific instructions of the solar panel supplier for the actual detailed arrangement, components and valves. 2. When using GreenGlo D series, solar collectors should be installed to the bottom coil - boiler, wetback or heaters should be installed to upper coil.
  • Page 11 GreenGlo Gas/Solid Fuel/Diesel plumbing connection diagram Important Notes: 1. The diagram shows generic drawings of connections to and from GreenGlo cylinder. Follow the specific instructions of the heater / boiler supplier for the actual detailed arrangement, components and valves. 2. The heater / boiler must have an integrated relief valve 3.
  • Page 12 Important Notes: 1. Applicable for GreenGlo D series only 2. The diagram shows generic drawings of connections to and from GreenGlo cylinder. Follow the specific instructions fof the heater / boiler supplier, the Solar Panels supplier and the Underfloor / Radiators or SPA supplier for the actual detailed arrangement, components and valves.
  • Page 13 GreenGlo Solar Wetback Heater/Boiler Underfloor Heating / Radiator / SPA - plumbing diagram Refer to the notes of page 11 © GreenGlo Limited Version 05/2010...
  • Page 14: Draining The Water Heater

    Turn off cold inlet supply at the 3 in 1 valve or at the meter • Open a hot water tap to drain the pipework • Disconnect the hot water outlet union • Open to atmosphere Cold Water Expansion Valve to let water flow via the • drain pipe © GreenGlo Limited Version 05/2010...
  • Page 15: Electrical Connection

    All electrical work must be carried out by a qualified person (per AS/NZS3000). All water heaters are manufactured for 230VAC, 50HZ single phase. GreenGlo 800D 1000D elements also capable to operate on a 3-phase 400VAC A flexible 20mm conduit is required for the electrical cable to the water heater Booster Elements and Thermostats setting: Adjust the thermostat temperature to the customer requirements.
  • Page 16: Sensors Connection

    Make sure that probes are pushed all the way into the sensor tubes. Use a thermal paste. Secure the probe cable Locate sensors above the electrical elements when required © GreenGlo Limited Version 05/2010...
  • Page 17 REGULAR CARE – SERVICE PERSON Anode Replacement GreenGlo 180S, 180D, 300S, 300D 1. Disconnect the power supply to the water heater 2. Drain approximately 5 to 10 lt. from cylinder as per page 13 instructions. 3. Unscrew service cap (11) gently 4.
  • Page 18 Anode Replacement GreenGlo 300DS to 1000D 6. Disconnect the power supply to the water heater. 7. Drain approximately 5 to 10 lt. from cylinder as per page 13 instructions. 8. 800D & 1000D: Drain entire water from cylinder as per page 13.
  • Page 19 Cylinder Coils Cleaning via Clearing Door Access door is located on the cylinder top for GreenGlo 180S to 300D models. Access door is located on the cylinder side for GreenGlo 300DS to 1000D. GreenGlo access door dimensions are designed to the European standards.
  • Page 20: Warranty

    WARRANTY GreenGlo Limited will repair or if necessary replace a defective water heater or parts failure due to faulty manufacturing as per the following schedule: Component Installation Warranty Coverage period All types of First 12 Repair or replace 100% water...
  • Page 21: Warranty Registration

    PO Box 35588 Browns Bay, Auckland Name: Address: Phone: email: Name of Installer: Main Application: e.g..Wetback, Solar, Gas, etc Domestic usage? Yes / No – if no specify: GreenGlo Water Heater Model: Product Serial Number: Notes: © GreenGlo Limited Version 05/2010...
  • Page 22 2 years TPR Valve check date: 30 months TPR Valve check: 3 years service by: date: 42 months TPR Valve check date: 4 years TPR Valve check date: 54 months TPR Valve check: 5 years service by: date: © GreenGlo Limited Version 05/2010...
  • Page 23 Replacement parts provided under this warranty does not carry a new • warranty. The unexpired warranty remains effective. GreenGlo Limited is only liable for the water heater and will not assume • directly or indirectly any other obligations in connection with the product GreenGlo Limited does not cover access labour replacement costs of •...
  • Page 24 Installer / Service Provider details www.greenglo.co.nz © GreenGlo Limited Version 05/2010...

This manual is also suitable for:

300s300d180d300ds400d500d ... Show all

Table of Contents