Page 1
User’s guide ‘‘CW750’’ series Architectural cabinet Replacement component list included This unit complies with the CSA and UL standards For further information or to consult this guide online, please visit our Website. INSCW7501108...
Page 2
If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings).
TROUBLESHOOTING PROBLEM DEFECTIVE PART OR PART TO CHECK - Defective thermostat or wrong thermostat setting - Open circuit breaker or fuse The unit does not work - Thermal protection activated - Faulty connections - Defective thermostat or wrong thermostat setting The unit runs continuously - Heat losses higher than the unit capacity - Defective thermal protection...
Page 5
REPLACEMENT COMPONENT LIST # REF. # PART DESCRIPTION # REF. # PART DESCRIPTION EA0300-06-*** ELEMENT 300W (600MM) M-GRI42521Z1 ALUMINUM GRILL (2100MM) EA0400-06-*** ELEMENT 400W (600MM) M-GRI42524Z1 ALUMINUM GRILL (2400MM) EA0450-09-*** ELEMENT 450W (900MM) PROT-101 LINEAR THERMAL PROTECTION (AUTO.) (L200) 600MM EA0600-09-*** ELEMENT 600W (900MM) PROT-102...
The warranty is limited to the repair or the replacement of the unit or the refund of its purchase price, at the discretion of Stelpro. Any parts replaced or repaired within the warranty period with the written authorization of Stelpro will be warranted for the remainder of the original war- ranty period.