Removing The Outdoor Fan Motor; Removing The Compressor - Mitsubishi Electric MSZ-G09SV Service Manual

Wireless type split-type, heat pump air conditioners
Hide thumbs Also See for MSZ-G09SV:
Table of Contents

Advertisement

OPERATING PROCEDURE

6. Removing the outdoor fan motor

(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller fan nut.
(3) Remove the propeller fan.
(4) Remove lead clamps and fan motor lead wires.
(5) Remove screws fixing the fan motor.
(6) Remove the outdoor fan motor.

7. Removing the compressor

(1) Remove the service panel, top panel and the cabinet.
(Refer to 1)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor.
(4) Remove the electrical assembly. (Refer to 2)
(5) Recover gas from the refrigerant circuit.
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(8) Remove nuts fixing the compressor.
(9) Remove the compressor.
NOTE
Before using a burner, reclaim gas from the pipes until the
pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
2
(0MPa).
Photo 5
Propeller fan
102
PHOTOS
Set screws of the
outdoor fan motor
Lead clamps
Welded
Propeller fan
parts
nut
Compressor set nuts

Hide quick links: