S-PIR from SeNd Technology is a PIR motion/heat detector
with SMS Alerts built-in. It is used primarily as a security system for houses, holiday
homes, garages and other buildings that you want to monitor movement in. When
alarm is activated, your system will text authorised mobile numbers in rotation until a
recipient responds. It will follow this text with a call which you can answer and through
its built in microphone, listen in at your site!
Sim Card registration - if you are using a PAYG Sim Card rather than a Contract Sim Card, you will need
Sim Card registration
Sim Card registration
Sim Card registration
to register your PAYG Sim Card and add credit to it by following network providers instruction's in the
booklet provided with your sim card. Make sure that any PIN codes are disabled.
Inser
Insert Sim card
t Sim card into device. Connect Antenna and Plug in power supply connector. Plug power supply
Inser
Inser
t Sim card
t Sim card
into mains socket.
System will start in 1-2minutes. If LED indicator is still blinking fast after this time, check SIM Card is
inserted properly and that PIN Code has been disabled.
Manufacturer's default password
text from Supervisor's mobile phone:-
pin at a later date: -
YYYY
a space.
To program the mobile numbers that will have access to and control the system, all numbers must be
To program the mobile numbers that will have access
To program the mobile numbers that will have access
To program the mobile numbers that will have access
entered with international country code ie 44 for UK. NR1 is mandatory and is the primary user.
Numbers should be entered based on priority since the system (upon alarm activation) will try to
contact the first entered number and in case of failure, will follow with the second etc. To add
recipients, send SMS message via text from any mobile:
XXXX
NR1:44ZZZZZZZZZZ
sp
are mobile numbers of alarm recipients without the prededing 0. ie
also program these numbers individually, one number at a time. To overwrite just repeat the process
for the NR you are overwriting with the new number. Ie to delete user in NR2 position, send the
following text:
XXXX
sp
Date and Time
Date and Time settings. Important to set these so system can send reports at specified times if you
Date and Time
Date and Time
require. Send the following SMS to the system:
mn–month, dd–day, hh–hour, mi–minutes eg.
By default, a status SMS message
a status SMS message will be sent daily at 11am to NR1. This message gives signal strength,
a status SMS message
a status SMS message
zone status and at the same time is a useful check system is operating. These parameters can be
configured to different time and period settings or disabled completely by sending SMS:
XXXX
INFO:00.00
Whilst any user can change these settings only NR1 will receive the status SMS.
sp
To arm or disarm the unit, authorised users can call the S-PIR (at no cost to them) and wait until the
To arm or disarm the unit
To arm or disarm the unit
To arm or disarm the unit
system drops the call (you will hear three rings for arming and one for disarming). Do not hang up until
you hear this. NR1 will receive a confirmation text of arm or disarm. When arming, if you are in the
zone, you will get 15 seconds to leave the zone and then confirmation of arming will be received
When unit is armed and m
delivered, NR2 will be texted and so on. If you prefer for all recipients to be informed jointly, this can be
programmed (see advanced manual). After SMS delivery, the unit will then ring recipients in set order
until a user picks up. If users answers, remote microphone switches on and user can listen to activity
at his site. Do remember if call diverts or voice mail is switch on at recipient's mobile, this will cut in if
you don't answer and your mobile will record microphone activity until voice mail stops (length of this
recording will vary according to your phone's voice mail settings but do note, this activity will use credit
from the unit's sim at your usual rate).
For further and advanced programming
advanced programming – see advanced user Guide at
advanced programming
advanced programming
password is four zeros 0000. You need to change this by sending the following
password
password
0000
PSW
XXXX
where YYYY is your old password. Small characters
sp
sp
NR2:44ZZZZZZZZZZ
sp
NR2:DEL
.
m otion is detected
otion is detected, system will send SMS message to NR1. If SMS cannot be
m m
otion is detected
otion is detected
PSW
XXXX
where XXXX is your chosen pin. To alter your
sp
sp
NR3:44ZZZZZZZZZZZ
sp
XXXX
MMMM.mn.dd
sp
7658
2010.09.22
12:28
sp
sp
where X is your chosen pin and Z's
7658 NR1:447898878549
hh:mi
where MMMM means year,
sp
= 22 Sept 2010, 12.28pm (pin 7658).
www.sendtech.co.uk
www.sendtech.co.uk
www.sendtech.co.uk
www.sendtech.co.uk
stand for
sp
You can

Advertisement

loading

Summary of Contents for SeNd Technology S-PIR

  • Page 1: Quick Start

    Whilst any user can change these settings only NR1 will receive the status SMS. To arm or disarm the unit, authorised users can call the S-PIR (at no cost to them) and wait until the To arm or disarm the unit...
  • Page 2: Safety Instructions

    The system must be powered by power supply source should not exceed 15VA power supply which • must be approved by LST EN60950-1 standard Any additional device connected to the S-PIR system must be powered up by a LST EN60950-1 • approved supply.