Set it upside down and measure it. Check that beam moves to the right and left
equally in quantity. Be careful at assembly that core does not tilt because
upward (downward)
magnetic
field by
coil moves the beam to the right (left) or type MS-50X microscope
of KANSAI DENKI.
l-3
Purity Adjustment
(This adjustment
method
applies to purity
adjustment
by hand operation.)
(1) Use an artificial magnetic
field and set the field
strength as follows,
*Magnetic
field in CPT axis direction: 0 Gauss
*Magnetic
field which is vertical to CPT axis:
U.S.A., Hawaii, Panama, Guam
Bolivia, Peru, Universal
. . . , . .0.3
Gauss
Canada
. . . . . . . . . . . . . . . . . .0.15 Gauss
Taiwan . . . . . . . . . . . . . . . . . . .0.37 Gauss
(The direction of the magnetic
field should be
from the left side to the right side of the CPT
screen as you face it.)
(2) Adjust Focus coarsely according
to item 2.
(3) Adjust Convergence
coarsely according
to item
1-4 and l-5.
(4) Receive Circle Pattern signal and check that
Contrast and Brightness are maximum.
(5) Receive magenta
signal. When the magenta
sig-
nal is not available, short-circuit
between
the
base and emitter of Q855 and set to magenta.
(6) .Press DY fully against CPT funnel and turn the
purity magnet so that the vertical magenta
band
comes to the center of the picture (Fig. 1-3-1).
Check that color uneveness
of both sides are
approximately
equal at this time.
The openings
of the purity magnet should be
symmetric
(Fig. 1-3-2).