Adams 1_1 online mp series User Manual

5/6/10kva

Advertisement

Quick Links

1_1 ONLINE MP SERIES
UPS
Single phase in / Single phase out
5/6/10kVA
USER MANUAL
UNINTERRUPTIBLE POWER SUPPLY UPS
1.
Important Safety Instruction..................................................... 2
1.1.
An Important Notice.............................................................. 2
1.2.
Storage Instruction................................................................ 3
2.
Product Introduction.............................................................. 4
2.1.
General Characteristics........................................................... 4
2.2.
Symbols on the LCD Display Panel............................................ 5
2.3.
Panel explanation.................................................................. 8
2.4.
Communication Port Explanation............................................... 11
3.
Installation and Operation........................................................ 12
3.1.
Unpacking.......................................................................... 12
3.2.
Selecting Installation Position...................................................13
3.3.
Installation of Accessories Kit................................................... 14
3.4.
Terminal Block Explanation..................................................... 15
3.5.
Operation Test and Installation Instruction....................................17
4.
Troubleshooting Guide........................................................... 28
4.1.
Trouble Shooting..................................................................28
5.
Bundled Software Installation Guide........................................... 30
5.1.
Hardware Installation............................................................. 30
5.2.
Software Installation.............................................................. 30
6.
Customer Options Slots.......................................................... 31
6.1.
R2E(2nd RS-232 ) card.......................................................... 31
6.2.
RSE(RS-485) card................................................................ 31
6.3.
USE(USB) card................................................................... 31
6.4.
DCE(Dry Contact)-B card....................................................... 32
6.5.
SNMP Cards....................................................................... 32
7.
Specifications...................................................................... 33
ENGLISH

Table of Contents

1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1_1 online mp series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adams 1_1 online mp series

  • Page 1: Table Of Contents

    Table of Contents 1_1 ONLINE MP SERIES Important Safety Instruction…………………………………………….. 2 1.1. An Important Notice…………………………………………………….. 2 1.2. Storage Instruction………………………………………………………. 3 Product Introduction…………………………………………………….. 4 2.1. General Characteristics………………………………………………….. 4 Single phase in / Single phase out 2.2. Symbols on the LCD Display Panel…………………………………….. 5 2.3.
  • Page 2: Important Safety Instruction

    1 Important Safety Instruction a. Medical equipment directly related to human life 1.1. b. Elevator, Metro (Subway) system or any other equipment related to An Important Notice human safety. 1.1.1 For parallel system installation, please refer to parallel installation guide. c.
  • Page 3: Product Introduction

    2.1.15 In case the UPS is out of order, Fault status will be shown on the LCD 2 Product Introduction screen 2.1.16 When the UPS is operated under CF50 or CF60 mode, the recommended load connected shall be 75% of rated capacity if the input 2.1.
  • Page 4 Indicate the item desired to be measured Er11 UPS Overheat UPS ON Switch or Alarm Silence UPS Output Overloading Er12 UPS OFF Switch Fan Error Er14 Previous Page or Setting Change Wrong Procedure to Enter Maintenance Mode Er15 Output Parameters Set Error in Parallel Next Page Er16 System...
  • Page 5: Panel Explanation

    2.3.2 Rear Panel Explanation 2.3. Panel explanation 2.3.1 Front Panel Function Explanations 5K/6K with batt Model LCD Display Green LED steadily lights up to indicate that Parall el Work Comm. RS232 Bus Not I ntended to TNV Communicati on Network Slot Ext.
  • Page 6: Communication Port Explanation

    A RS232 Port B Terminal Resistor for Parallel function 2.4. Communication Port Explanation C CAN Bus Connection Port for Parallel System D Customer Options Slot 1 The Communication port on the UPS provides true RS232 type to E Customer Options Slot 2 communicate with UPS software to remote monitoring the power and UPS status.
  • Page 7: Installation And Operation

    3 Installation and Operation 3.2. Selecting Installation Position It is necessary to select a proper environment to install the unit, in order to The packing condition and the external outlook of the unit should be inspected minimize the possibility of damage to the UPS and extend the life of the UPS. carefully before installation.
  • Page 8: Installation Of Accessories Kit

    3.3. Installation of Accessories Kit 3.4. Terminal Block Explanation Tower model OUTPUT INPUT BYPASS (DIM TYPE ONLY) INPUT UTILITY INPUT N22, L22, N21, L23, L21: UPS OUTPUT L11-N1: BYPASS INPUT (DIM TYPE ONLY) : OUTPUT EARTH GROUND L12-N1: UTILITY INPUT : INPUT EARTH GROUND Rack 5/6K Rack 10K...
  • Page 9 L12-N1: the terminal for Utility Input to provide the power source when theUPS is Model Maximum Current Conductor Section working under Utility mode. G1: the terminal for UPS Input Ground. 5/6KVA L21 L23 N21 L22 N22: the terminals for UPS Output. 10KVA G2: the terminal for UPS Output Ground.
  • Page 10: Operation Test And Installation Instruction

    3.5.1.5 Then, the UPS is on Bypass Mode now and it will proceed self-test 3.5. Operation Test and Installation Instruction automatically. If there is no abnormal message occurred, it means the pre- startup of the UPS is successful and the charger starts to charge the 3.5.1 Start Up in Normal Mode batteries.
  • Page 11 * It shows Utility input is “0” and Utility Abnormal. * It shows “220Vac” in Utility Input. 3.5.1.9 In case of failure in self-test, the LCD display will illustrate from Drawing D to drawing E2, then an error code or error status will be shown on the screen.
  • Page 12 * It shows frequency from Bypass Input. * It shows UPS Inner Temperature 3.5.4 UPS Default Data and Special Function Execution 3.5.4.1 After UPS completely starts up, press key pad to change the LCD display screen to drawing Q1. * It shows UPS output Voltage. * It shows buzzer “On”.
  • Page 13 * It shows inverter output voltage. * It shows self-test is NOT “on”. * It shows the UPS is operated in “normal mode”. * It shows self-test is “On”. * It shows the UPS is operated in “Eco mode”. * It shows Bypass Voltage is adjusted to narrow one. * It shows the UPS is operated in “CVCF 50Hz mode”.
  • Page 14 3.5.5.4 Drawings S1 and S2 mean the bypass input acceptable window, it can be 184Vac~260Vac or 195Vac~260Vac. 3.5.5.5 Drawing T means the bypass frequency window of the Inverter Output, the acceptable setting values are ±3Hz and ±1Hz. 3.5.5.6 Drawing U means the acceptable Inverter Output Voltage, of which voltage is 200Vac, 208Vac, 220Vac, 230Vac, or 240Vac.
  • Page 15: Troubleshooting Guide

    4 Troubleshooting Guide 4.1. Trouble Shooting 3.5.6 UPS Is Off Due to Unknown Reason and Its Trouble Shooting When the UPS malfunctions during operation, you may check the followings: 3.5.7 a. Are the wirings of input and output correct? 3.5.7.1 If there is a serious abnormal condition occurred, the UPS will lock it b.
  • Page 16: Bundled Software Installation Guide

    5 Bundled Software Installation Guide UPS fails to offer If the backup time is still too battery backup or its short after 8 hours of charge, 5.1. Hardware Installation back up time is shorter please contact your local than its calculation. distributor for battery 1.
  • Page 17: Customer Options Slots

    6.4. 6 Customer Options Slots DCE(Dry Contact)-B card 6.4.1 The pin assignments of 10-Pin Terminal: 6.1. R2E(2nd RS-232 ) card 1 2 3 4 5 6 7 8 9 10 6.1.1 CN1 is for RS232 DB9 6.1.2 For communication protocol, please Pin 1: UPS on Bypass mode.
  • Page 18: Specifications

    7 Specifications ALARMS Model 5000VA/6000VA 10000VA Audible and Visual Line Failure, Battery Low, Transfer to Bypass, INPUT System Fault Conditions Voltage Window 160~280Vac* PHYSICAL Frequency 45 ~ 65 Hz Dimensions 440x88x680 440x176x680 power module Phase/Wire Single, Line + Neutral + Ground (HxWxD)mm 440x176x680 With batteries...
  • Page 19 192321132015003...