Connecting the pressure relief valve (PRV)
A listed pressure relief valve supplied with the heater must
be installed at the time of installation. No valve is to be
placed between the PRV and the heater. No reducing
coupling or other restriction may be installed in the discharge
line. The discharge line must be installed such that it allows
complete drainage of both the PRV and the line. The location
of the PRV must be readily accessible for servicing or
replacement, and be mounted as close to the water heater
as possible. See Fig 7. To install the PRV, a suitable fitting
connected to an extension on a "T" fitting can be sweated
to the hot water line.
PIPE PRV TO
APPROPRIATE
DISCHARGE
HOT
Fig. 7 - Pressure Relief Valve
OPERATING INSTRUCTIONS
Before proceeding with the operation of the heater make
sure that the system is filled with water.
Open the cold water inlet supply to the heater fully.
Open a hot water faucet to permit the water to fill the heater
and the piping and to eliminate the air trapped in the system
Close the hot water faucet after the water flows freely and
all the air has escaped from the system. The water heater
is now ready to operate.
FOR YOUR SAFETY READ BEFORE LIGHTING
THE PILOT
Warning: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life
A. This appliance has a piezo-igniter for lighting the pilot
burner. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
12
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone
- Immediately call your gas supplier from a neighbor's
- If you cannot reach your gas supplier, call the fire
C. Use only your hand to push in or turn the gas control
buttons. Never use tools. If a button will not push in, check
to make sure the buttons are being pushed in the proper
sequence. Follow these instructions exactly. If control
button(s) are jammed, close the gas supply and call a
qualified service technician. Attempted forceful repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

of heater)
1. STOP! Read the safety information above on this plate.
2. The gas valve must be turned off by depressing the gas
3. Wait five (5) minutes to clear out any gas. If you smell
4. The pilot burner is located behind the peephole in the
COLD
5. Depress PILOT button (
6. Observe the pilot flame through the peephole. The pilot
- If the gas valve button does not pop up when released,
- If pilot does not stay lit, repeat steps 1 through 6.
- If pilot will not stay lit after several tries, depress the OFF
7. When lit, depress the ON button (
TO TURN OFF GAS TO APPLIANCE
Depress the OFF button (
the heater.
in your building
phone. Follow the gas supplier's instructions.
department.
valve off button (
).
gas, STOP! Follow "B" in the safety information above
on this plate. If you don't smell gas, go to the next step.
front center of the jacket directly below this instruction
plate.
PILOT INGITER button (
repeated.
button ( ) should be held down at least 15 seconds with
pilot burning. When the pilot button is released the pilot
should continue to burn.
stop and immediately call your service technician or gas
supplier.
button ( ), and call your service technician or gas supplier.
now fire when water is drawn at a rate greater than the
threshold flow rate.
NOTE: If main burner should fail to ignite, make sure pilot
is burning. If not, repeat lighting steps 1 through 6.
(as seen on front cover
) and light pilot by pushing
). This may have to be
). The heater will
) and close the gas supply to