Knife stroke

05.02
Requirement
The knife stroke can be set within a range of 1.0 to 3.5 mm for the ideal adaptation to all
materials used.
Fig. 13 - 25
Turn the eccentric 1 ( screws 2 ) so that the mark of the desired cutting stroke is
opposite the mark on the clamp collar 3.
Adjustment
3
3,5
1
2
13 - 30