Installing Batteries

1. Connect 2-Wire Harness:
- Positive (Red) to Battery A Positive
- Negative (Black) to Battery A Negative
2. Connect Fuse and Black Connector Harness:
- Positive (Red) to Battery B Positive
- Negative (Black) to Battery B Negative

Removing Batteries

1. Remove the two 5/16" bolts on the rear suspension link bar using a ¼"
allen wench then removethe bar.
2. Loosen the two top 5/16 bolts and two 5/16 nuts with a ½"wrench on the
battery tray on the rear of the chair.
3. Grab the anti-tip wheels and slide the battery tray out from the base frame
slowly watching the wiring harness.
4. Pull the 50 amp circuit breaker out, and then remove the wires from the ¼"
screw terminals with a 7/16"wrench.
5. Undo the battery hold down strap, and remove batteries one at a time.
6. Installation: follow steps in reverse order. Note above picture for battery
and wiring harness orientation
7. Ensure the Red wires to positive (+) terminals and Black to negative (-)
and terminal covers are completely over the bolts and terminals.
+
Black Connector
+
Blue Connector
-
50 Amp Fuse