Vallox 70 COMPACT R Instructions For Use Manual page 7

Supply and extract air ventilation with heat recovery
Hide thumbs Also See for VALLOX 70 COMPACT R:
Table of Contents

Advertisement

VALLOX 70 COMPACT
POST-HEATING
For most of the year, heat recovered from the air being extracted is enough to warm the cold
air coming from the outside to a suitable temperature. If the heat of extract air is not enough,
air coming from the outside may be heated further with the radiator delivered with the unit.
How the post-heating radiator works
Effect of outdoor air flow and
outdoor air temperature on
supply air
1. Supply air heated by extract air
2. Maximum temperature
• 900 W post-heating radiator can
heat air flowing at the speed of
/s by circa 8 °C.
50 dm
3
• Temperature of air coming to the
unit is 20 °C.
Electric radiator
VALLOX 70 COMPACT comes standard with a max. 900 W electric radiator used for heating
supply air. The temperature of supply air is adjusted at the thermostat regulator located inside
the unit. Temperature adjustment range is +0...+25 °C.
It is advisable to set the thermostat at 0 °C in summer. In this case, the radiator does not heat
air, as the heat recovery cell is bypassed.
Note!
Post-heating represents comfort heating. It is not necessary for the functioning of the system
as such. What this means is that if the dwelling is heated by something else than direct
electric heating, it is worthwhile to minimize post-heating (supply air) temperature in order
to save electricity.
Temperature of supply air going from the unit to the dwelling
Antifreezing starts to function
˚C
max
25
20
10
0
-30
-20
-10
-0
Temperature of outdoor air coming to the unit
7
INSTRUCTIONS FOR USE
2
1
10
20
˚C
© VALLOX • We reserve the right to make changes without prior notification.
What the units include can vary depending on the sales area.