Chemical Advice; Maintenance; Cleaning; Filters - C-Dax SPRAY-ON 200 Series Owner's Manual

Spot/boom sprayer
Table of Contents

Advertisement

Chemical Advice

C-Dax Ltd or their agents cannot make recommendations or give advice as to the use of chemicals and cannot accept
responsibility for any damage, injury or other consequence for disregarding this warning notice. Contact your chemical
supplier for advice.

Cleaning

Clean the sprayer regularly! After each use flush the unit out three times with fresh water. Use CDAX Neutralise for the
second rinse.
To prevent damage to the sprayer and spray gun, drain the water from the sprayer and spray gun when there is a risk of

Filters

The tank strainer basket is retained by the lid to assist cleaning. Always clean the strainer before filling the tank with
spray solution.
Clean all filter screens regularly.
If the pump is observed to be leaking from between the motor and black pump body or from the motor itself, cease
operation and have the pump serviced immediately. C-Dax Ltd and their distributors have a comprehensive parts
inventory and capable staff. Because of the complications of the pump it may be best to get your C-Dax agent to post it
C-Dax Ltd and their distributors have a comprehensive parts inventory and capable service staff.
Repairs should only be undertaken by C-Dax, or an authorised C-Dax service centre.
Switch on but pump does not
operate
Pump runs but does not stop.
Pump runs but pulses while
pumping
Fluid leaks from drain holes in
pump

MAINTENANCE

CAUTION
frost.
NOTE
back to the authorised service centre.

TROUBLESHOOTING

1. Blown fuse
2. Pressure switch operated
3. Pressure switch failed
4. On/Off switch failed
1. Spray gun trigger open
2. Air lock in pump
3. Suction hose loose
4. Dirt or spray residue in
pump valves
5. Blocked suction filter mesh
1. Spraying pressure higher
than the pump shut off
pressure
2. Pump shut off pressure too
low
1. Internal leak within pump
head
6
Check wiring and replace
15A fuse
Operate spray gun trigger
Replace pressure switch
Replace switch
Close trigger
Operate spray gun trigger
until all air is expelled from
the pump and hose.
Check and tighten all
suction hose connections
between pump inlet and
tank.
Replace valves.
Clean filter mesh.
Reduce spraying pressure
by opening the adjustable
spray tip.
Increase pump shut off
pressure. Refer
maintenance.
Remove pump for
servicing.

Advertisement