Converting The Lower Element - Kenmore 153.321344 Use & Care Manual

Electric
Table of Contents

Advertisement

Converting
the Lower Element
These instructions only cover the conversion of the convertible
element, read this entire manual before attempting
to install
or operate the water heater. The water heater is factory set to
operate at 3800 watts. The lower element can be converted to
operate at 5500 watts. Refer to "Facts to Consider About the
Convertible Lower Element" section.
The Upper Element, (if double element model)is a conventional
3800 watt element which only operates at its rated wattage on
240 volts. (See rating plate on the water heater.
The lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
If after reading these instructions and this manual, if you do not
understand any portion call Sears Service Center.
Fire Hazard
/ Electric
Shock
Hazard
Necessary element conversion parts are located in a small bag
contained within the electrical junction box on top of the water
heater.
CONVERSION
PARTS
BUSS BAR
1.
FIGURE 12.
Before beginning the conversion turn "OFF" electric power
supply to the water heater.
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure to use the correct voltage
shown
on the model rating plate
could result in death, serious bodily
injury, or property damage.
Before making the conversion to 5500 watts, make sure that the
(1) power supply is 240 volts, (2) the wiring is 10 gauge AWG
@ Type TW, 60°C or equivalent, and (3) the circuit breakers
or fusing are capable of 30 amp loading. Also, the installation
must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.
NOTE: Whether or not the element conversion
is made the
model rating plate must be marked. Using a hard point ink pen,
check the appropriate block within the model rating plate, which
is located adjacent to the lower access panel.
ELECTRIC
@
LISTED
WATER
HEATER
932N
CAPACITY
MODEL
NUMBER
U,B.
GAL,
SERIAL
NUMBER
FACTORY
EQUIPPED
WITH
MAXIMUM
UPPER
LOWER
CHECK
HERE
WORKING
ELEMENT
ELEMENT
MAXIMUM
VOLTS
IFINSTALLEDAS
PRESSURE
WATTS
WATTS
WATTS
A.C.
ONLY
FACTORY
EQUIPPED
P,S,I.
OPTIONAL
WATTAGE
UPPER
LOWER
ELEMENT
ELEMENT
MAXIMUM
CHECK
HERE
WATTS
WATTS
WATTS
IF CONVERTED
WARNING
SEE
CONVERSION
INSTRUCTION
FIGURE 11.
13
FIGURE 13.
2. The convertible element is located behind the lower access
panel of the water heater. Remove the screw securing the
access panel, and remove panel.
FIGURE 14.
3.
Fold the insulation back to expose the terminal cover.
--...
FIGURE 15.
4. Lower Element: Lift out the tab as shown to unclip the terminal
cover from the thermostat. The terminal cover can now be
removed from the thermostat.

Hide quick links: