CTs Power Amplifiers
8 AC Power Draw and
Thermal Dissipation

AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle (8.4 Ohm mode )
At Idle (70/100V mode)
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
Operation Manual
Rated
Line Current
Load
Power
8 Ohms/Ch.
200x4
16 Ohms Bridge
400x2
4 Ohms/Ch.
260x4
8 Ohms Bridge
520x2
70V/Ch.
220x4
100V Bridge
220x2
8 Ohms/Ch.
200x4
16 Ohms Bridge
400x2
4 Ohms/Ch.
260x4
8 Ohms Bridge
520x2
70V/Ch.
220x4
100V Bridge
220x2
CTs 4200
Line Current
120VAC
230VAC
watts in
70
114
5.2
2.6
400
7.8
3.9
639
5.3
2.7
427
7.6
3.8
648
11.8
5.9
1005
7.9
4.0
668
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
70
239
0
114
389
99
301
1027
134
505
1722
110
318
1084
257
391
1336
349
655
2236
286
382
1303
kcal/hr
60
98
259
434
273
337
564
329