Self-Diagnostic Function - Sony KV-29FS140 TRINITRON Service Manual

Color television
Table of Contents

Advertisement

The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED indicator will automatically begin to fl ash. The number of
times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY LED fl ash indicators is listed in the instruction manual
for the user's knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure occurrence
data stored in memory to reveal past problems and how often these problems occur.
1. Diagnostic Test Indicators
When an error occurs, the STANDBY LED indicator will fl ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the indicator will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a "0".
Diagnosis
Item
Description
Indicator flashes
• No Power
• +B overcurrent
(OCP)
• Vertical NG.
• IK (AKB)
• Supply Voltage
Protection
*One fl ash count is not used for self-diagnostic.
*If a +B overcurrent is detected, stoppage of the vertical defl ection is detected simultaneously. The symptom that is diagnosed fi rst by the mircrocontroller
is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
2. Display of STANDBY LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
KV-29FS140

SELF-DIAGNOSTIC FUNCTION

No. of times
STANDBY
Diagnostic Result
on screen display
Does not light
2 times
2 OCP:0
2 OCP:1 ~ 255
4 times
4 VSTOP:0
4 VSTOP:1 ~ 255
5 times
5 AKB:0
5 AKB:1 ~ 255
8 times
8 SUP:0
8 SUP:1 ~ 255
LED OFF
3 sec.
Probable
Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out (F4101)
(H1 Board)
• H.OUT (Q511) is shorted.
(A board)
• IC751 is shorted.
(C/CV Board)
• +13V is not supplied.
(A Board)
• IC503 voltage list is faulty.
(A Board)
• Video OUT (IC751) is faulty.
(CV Board)
• IC001 is faulty. (A Board)
• Screen (G2) is improperly
adjusted.
• IC604 faulty.
• IC607 faulty.
Standby indicator
KV-29FS140
Self Diagnosis
Supported model
Detected
Symptoms
• Power does not turn on.
• No power is supplied to the
TV.
• AC power supply is faulty.
• Power does not turn on.
• Load on power line is
shorted.
• Has entered standby state
after horizontal raster.
• Vertical deflection pulse is
stopped.
• Power line is shorted or
power supply is stopped.
• No raster is generated.
• CRT cathode current
detection reference pulse
output is small.
• No power supply to CRT
ANODE.
• No RASTER is generated.
7