• DK-39E BOARD IC2101 µPD72069GF-3BA (FLOPPY DISK DRIVE CONTROLLER)
Pin No.
Pin Name
1
NC
2
GND3
3
NC
4
EM2
5
EM1
6
GND3
7
EM0
8
DIR
9
GND3
10
STEP
11
WDATA
12
GND3
13
WE
14
ENIDX
15
NC
16
VDD2
17
NC
18
CGP1
19
NC
20
CGP2
21
GND2
22
LPF1
23
LPF2
24
TRK0
25
NC
26
WPRT
27
RDATA
28, 29
NC
30
READY
31
2SIDE
32
FLT
33
ENPCS
34
ACTL
35
MSEL
36
SIDE
37
GND3
38
FLTR
39
HDLD
40
GND3
41
LCT
42, 43
VDD1
I/O
Not used (open)
Ground terminal (buffer system)
Not used (open)
O
Spindle motor on/off control signal output of the drive unit Not used (open)
O
Spindle motor on/off control signal output of the drive unit Not used (open)
Ground terminal (buffer system)
O
Spindle motor on/off control signal output of the drive unit Not used (open)
Signal specifying the seek direction is output to the floppy disk drive unit
O
"L": centripetal direction, "H": centrifugal direction
Ground terminal (buffer system)
O
Signal generating seek pulses is output to the floppy disk drive unit
O
Written data output to the floppy disk drive unit
Ground terminal (buffer system)
O
Signal specifying data writing to drive is output to the floppy disk drive unit
Signal that makes INDEX signal and RDATA signal active is input from the floppy disk drive
I
unit Fixed at "L" in this set
Not used (open)
Power supply terminal (+5V) (analog system)
Not used (open)
O
Phase error in sub PLL system is output
Not used (open)
O
Phase error in sub PLL system is output
Ground terminal (analog system)
O
Phase error in main PLL system is output
O
Phase error in main PLL system is output
Signal showing that the head of drive positions at cylinder 0 is input from the floppy disk drive
I
unit
Not used (open)
I
Signal showing that the medium is in write protect status is input from the floppy disk drive unit
I
Read data input from the floppy disk drive unit
Not used (open)
I
Signal showing that the drive is ready is input from the floppy disk drive unit
Signal showing that a both sided medium is inserted in the drive is input
I
Not used (fixed at "L")
I
Signal showing that the drive is in fault status is input Not used (fixed at "H")
I
Not used (fixed at "L")
Initial setting signal to select active level of drive interface signal is input
I
Fixed at "H" in this set (Set the active level is "L")
I
Not used (fixed at "L")
O
Signal selecting the head of both sided drive is output to the floppy disk drive unit
Ground terminal (buffer system)
O
Signal to reset the drive fault status is output Not used (open)
O
Signal setting the head of drive in load status is output Not used (open)
Ground terminal (buffer system)
Signal showing that the head of drive positions at the inside from No. 43 cylinder is output
O
Not used (open)
Power supply terminal (+5V) (digital system)