Step 3:
After entering the CREATE VOLUME MENU screen, enter a volume name with 1~16 letters (letters cannot be
special characters) under the Name item and press <Enter>. Then, select a RAID level (Figure 11). RAID levels
supported include RAID 0, RAID 1, RAID 10, and RAID 5 (the selections available depend on the number of the
hard drives being installed). Press <Enter> to proceed.
Intel(R) Rapid Storage Technology - Option ROM - Option ROM - 13.1.0.2126
[ hi ]-Change
Step 4:
Under Disks item, select the hard drives to be included in the RAID array. If only two hard drives are installed,
they will be automatically assigned to the array. Set the stripe block size (Figure 12) if necessary. The stripe block
size can be set from 4 KB to 128 KB. Once you have selected the stripe block size, press <Enter>.
[ hi ]-Change
Configuring SATA Hard Drive(s)
Copyright (C) Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
Name : Volume0
RAID Level :
Disks :
Strip Size :
Capacity : 931.5 GB
Sync : N/A
RAID 0: Stripes data (performance).
[TAB]-Next
Figure 11
Intel(R) Rapid Storage Technology - Option ROM - 13.1.0.2126
Copyright (C) Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
Name : Volume0
RAID Level : RAID0(Stripe)
Disks :
Strip Size :
Capacity : 931.5 GB
Sync : N/A
The following are typical values:
RAID0
RAID10 - 64KB
RAID5
[TAB]-Next
Figure 12
RAID0(Stripe)
Select Disks
16KB
Create Volume
[ HELP ]
[ESC]-Previous Menu
Select Disks
16KB
Create Volume
[ HELP ]
- 128KB
- 64KB
[ESC]-Previous Menu
- 74 -
[ENTER]-Select
[ENTER]-Select