COEF srl. Via Albinatico, 80-82 51019 Ponte Buggianese (PT) ITALY www.coef.it / www.coef.net info@coef.it • Code 02E004 • OPERATING INSTRUCTIONS Printed in October 2000...
Page 2
Le descrizioni ed illustrazioni fornite nella presente pubblicazione non sono impegnative. COEF srl. si riserva il diritto di apportare in qualsiasi momento tutte le modifiche che riterrà opportune. Il presente manuale non può essere ceduto in visione a terzi senza spe- cifica autorizzazione scritta dalla COEF srl.
Please find here below a list of symbols and relative meaning. OPERATOR: Not particulary qualified staff, that can operate when no specific knowledge is required. COEF OPERATOR Technical staff, qualified and trained by the constructor, for repair and extraordi- nary operations.
Adjust the three screws (part. B) until you reach the ideal condition between power and homogeneity. WARNING! The lamp is pre-regulated by the factory. Only fine-adjustment is required. Don’t move the screws B up to upper or lower extremities. http://www.coef.net - info@coef.it Pag. 5...
PROJECTOR INSTALLATION To fix the MP250 Fresnel is necessary, when the installation has to be on a raised-from-the ground support, to block the fixing bracket of the unit by means of a screw provided with nut and locknut measuring not less than M10X50, to insert in the central pre-arranged hole on the fixing bracket.
Connect the projector to the control unit by means of a RG58 or RG59 coaxial cable supplied with 3 Pin XRL Cannon plugs and connectors. Respect, according to the indications on the panel, the input and the output of the DMX 512 signal. FROM CONTROL UNIT http://www.coef.net - info@coef.it Pag. 7...
CH89 function, MISC menu (see Table 4.1 Menu/Fuctions), we shall be able to check the MP250 Fresnel with the 1 to X channels (8 or 9 according to how the setting is) of the DMX line.
180° rotation of the visualization display SWPT (*) STND / SWAP Channel control switch PAN / TILT CH 8/9 (*) CH 8 / CH 9 Pojector control (8 or 9 channels) Show the installed software version http://www.coef.net - info@coef.it Pag. 9...
ORDINARY MAINTENANCE The ordinary maintenance is fundamental for the perfect efficiency of MP250 Fresnel, in order to prevent any functional defect as a reduced light beam or irregularities in the movement of the pro- jector or of other rotating parts.
( color 1, color 2, shutter etc.). WARNING! An improper use of this documentation made by not specifically qualified staff can damage irremediably the electronic and/or mechanical components of the projector. Pag. 14 Http://www.coef.it - info@coef.it...
Set ON ENCO Function of PAN/TILT con- figuration MENU (cap. 4.1) The projector does not carry out - ENCO OFF in the PAN/TILT confi- the automatic repositioning of the guration menu Technical aid is required. PAN or TILT movements. http://www.coef.net - info@coef.it Pag. 15...
We, Manufacturer/Importer COEF srl. Via Albinatico, 80-82 51019 Ponte Buggianese (Pistoia) ITALY Declare that the product MP250 Fresnel Is in conformity with 89/336 EEC-EMC In accordance with Directive and With the actual required safety standards in accordance with LVD 73/23 EEC...
Need help?
Do you have a question about the MP250 FRESNEL and is the answer not in the manual?
Questions and answers