24
Error Codes
 
QR code  SOURCE PROBLEM 
Tank Heat timeout 
  
  
  
  
  
  
  
  
No / low water flow 
  
  
  
  
Tank Over‐ Temperature 
  
  
  
  
  
  
Open thermistor 
General fault 
ENGLISH
Engineering Department 
Erros codes for Mother Parker's Single Cup Brewer 
TO BE PERFORMED BY QUALIFIED SERVICE TECHNICIAN 
PROBABLE CAUSE 
Heater failure 
Harness opens 
Triac board failure 
Limit switch open 
Control board failure 
Pump failure 
Harness opens 
Control board failure 
Scale build up in tank assembly 
Triac board failure 
Use of hot water in reservoir 
Hot water bypassing into reservoir 
while brewing 
Brewer will not operate at all 
Various 
 
CORRECTIVE ACTION 
Measure resistance across heater 
leads.  If open, replace tank assem‐
bly. 
Check conductivity between heater 
leads and board.  Replace if 
needed. 
Replace triac board 
Replace tank assembly 
Replace control board 
Apply 24VAC to pump to check 
operation.  Replace if needed. 
Check conductivity between pump 
leads and board.  Replace if 
needed. 
Replace control board 
Delime tank or replace tank if 
needed. 
Replace triac board 
Check user interaction 
Check high pressure bypass check 
valve.  Pull tube off of top of tank 
and blow air towards reservoir.  If 
air comes out, replace.  Pressure is 
11PSI nominal. 
Check thermistor harness connec‐
tion.  Measure thermistor resis‐
tance 30K @ 75F.  Replace tank 
assembly if needed. 
Check latest service materials on 
website 
24