Summary of Contents for Cross Technologies 1584-45
Page 1
POWER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies.
1.1 Equipment Description The Model 1584-45 is four, five way, 0.95 - 2.05 GHz, 0 dB gain splitters in a 1 Rack Unit chassis with redundant 100-240 ±10% VAC power supplies. Each splitter provides fused DC power insertion on the input connector center pin, surge protection, and excellent RF characteristics.
2.0 Installation 2.1 Mechanical The 1584-45 consists of one RF printed circuit board (PCB) housed in a 1 RU (1 3/4 inch high) by 12 inch deep chassis. Redundant, switching, +24 VDC power supplies with the DC output diode OR’d provide redundant power for the internal and external amplifiers and LEDs.
Fast Blo, 5mm fuse Fast Blo, 5mm fuse Blo, 5mm fuse Blo, 5mm fuse FIGURE 2.2 1584-45 REAR PANEL 2.3 Front Panel Monitors and Indicators Figure 2.3 shows the front panel monitors and indicators. DS3 - LNB2 VOLTAGE LED DS1 - LNB 4 VOLTAGE LED...
Operation 1.) Connect RF cables to the 1584-45 (See Section 2.2). 2.) IF DC VOLTAGE IS REQUIRED ON THE SPLITTER RF INPUT CENTER CONDUCTOR, install 1/4”, 1 amp fast blo fuses in Fuse 3 and/or Fuse 4 holders. CAUTION! -- IF FUSES ARE INSTALLED IN THE Fuse 1, 2, 3, or 4 HOLDERS, +22 VDC WILL APPEAR ON THE CORRESPONDING SPLITTER INPUT CONNECTOR CENTER PINS.
If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1584-45 Manual, Rev C Page 8 4/24/13...